Deployment Details
Survey: - SS200704 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 83
Operation No.: 1
Gear: Autosal Salinometer,CTD 20 - SN 0552,Conductivity CTD 20-SN 3169,Fluorometer-CTD20-Chelsea-06-5941-001,Licor - CTD 24 - SN 70111,Oxygen-CTD 20-Optode SN 716-Foil 4804,Pressure CTD 20-SN 75638,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,Quikchem 8000 series auto analyzer,SCRIPPS Automated Photometric Oxygen System,Temperature CTD 20-SN 2751,Transmissometer - CTD 20 -CST-1016DR
When: 2007-05-30 07:34 to 2007-05-30 08:12 UTC
Where:
26° 00.4' S
112° 12.1' E
to
26° 00.8' S
112° 11.6' E
Maximum Depth (m): 454
CTD profile - view full size
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.Bottle Data
Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Silicate (µM) |
---|---|---|---|---|---|---|---|---|
1068 | 1.8 | 23.21 | ||||||
1070 | 1.9 | 23.21 | ||||||
1065 | 2.2 | 23.21 | ||||||
1064 | 2.2 | 23.21 | ||||||
1062 | 2.2 | 23.21 | ||||||
1063 | 2.5 | 23.21 | ||||||
1061 | 2.6 | < 0.02 | 23.21 | 0.03 | < 0.02 | 2.06 | ||
1066 | 2.7 | 23.21 | ||||||
1069 | 2.9 | 23.21 | ||||||
1060 | 24 | 219.10 | 35.569 | < 0.02 | 23.06 | 0.04 | < 0.02 | 2.08 |
1059 | 48.4 | < 0.02 | 22.95 | 0.06 | < 0.02 | 2.15 | ||
1058 | 72.7 | < 0.02 | 22.89 | 0.05 | < 0.02 | 2.14 | ||
1067 | 87.5 | 0.29 | 22.86 | 0.07 | 0.05 | 2.52 | ||
1056 | 97.1 | 0.21 | 22.49 | 0.13 | 0.12 | 3.24 | ||
1055 | 107.6 | 0.99 | 22.15 | 0.08 | 0.10 | 2.42 | ||
1054 | 117.8 | 0.15 | 21.87 | 0.09 | 0.06 | 2.40 | ||
1053 | 248.3 | 223.60 | 35.746 | 2.42 | 16.80 | 0.27 | < 0.02 | 1.77 |
1052 | 446.9 | 16.47 | 9.22 | 1.17 | < 0.02 | 4.61 |
Gear / Instruments used.
Instrument | Manufacturer | Model | Serial No | Measuring |
---|---|---|---|---|
Autosal Salinometer | Guildline Instruments | 8400B | SN 62021 | Salinity (psu) |
CTD 20 - SN 0552 | Seabird | SBE II plus | 0552 | |
Conductivity CTD 20-SN 3169 | Seabird | SBE-4 | 3169 | |
Fluorometer-CTD20-Chelsea-06-5941-001 | Chelsea | Aquatracker | 06-5941-001 | Fluorescence (arbitrary units) |
Licor - CTD 24 - SN 70111 | QCP | 2300 | 70111 | PAR (uE/m**2/sec) |
Oxygen-CTD 20-Optode SN 716-Foil 4804 | Aanderaa | Optode 3975 | 716 | Optode (micromole/litre) |
Pressure CTD 20-SN 75638 | Paroscientific I | 410K-105 | 75638 | Pressure (decibars) |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Silicate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Orthophosphate (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Ammonia (µM) | |
Quikchem 8000 series auto analyzer | Lachat Instruments | 8000 Series | Nitrate (µM) | |
SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
Temperature CTD 20-SN 2751 | Seabird | SBE-3 | 2751 | Temperature (deg C) |
Transmissometer - CTD 20 -CST-1016DR | WET Labs | C-Star | CST-1016DR | Transmittance (%) |