Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 54
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-22 05:01 to 2025-06-22 05:41 UTC
Where: 38° 17.7' S 149° 14.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 1.6 | 239.78 | 35.578 | 2.80 | 16.41 | 0.32 | 0.06 | 0.34 | 1.16 |
| 34 | 1.9 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 2 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 25.5 | 238.94 | 35.577 | 2.86 | 16.29 | 0.33 | < 0.02 | 0.36 | 1.21 |
| 32 | 39.5 | < 0.02 | < 0.02 | < 0.02 | 16.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 39.6 | < 0.02 | < 0.02 | < 0.02 | 16.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 39.6 | < 0.02 | < 0.02 | < 0.02 | 16.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 39.6 | 238.18 | 35.577 | 2.89 | 16.27 | 0.32 | < 0.02 | 0.36 | 1.18 |
| 27 | 100.6 | 214.46 | 35.462 | 6.40 | 15.69 | 0.55 | < 0.02 | 0.17 | 2.13 |
| 28 | 100.6 | < 0.02 | < 0.02 | < 0.02 | 15.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 125.9 | < 0.02 | < 0.02 | 7.17 | 15.37 | 0.59 | < 0.02 | 0.12 | 2.36 |
| 26 | 125.9 | < 0.02 | < 0.02 | < 0.02 | 15.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 150.5 | < 0.02 | < 0.02 | 9.34 | 14.73 | 0.73 | < 0.02 | 0.03 | 3.00 |
| 24 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 14.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 169.7 | < 0.02 | < 0.02 | 9.74 | 14.46 | 0.76 | < 0.02 | 0.03 | 3.16 |
| 22 | 169.7 | < 0.02 | < 0.02 | < 0.02 | 14.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 199.4 | 205.49 | 35.277 | 10.46 | 13.97 | 0.79 | < 0.02 | 0.03 | 3.45 |
| 20 | 199.4 | < 0.02 | < 0.02 | < 0.02 | 13.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 219.4 | < 0.02 | < 0.02 | 10.38 | 13.76 | 0.79 | < 0.02 | 0.02 | 3.39 |
| 18 | 219.4 | < 0.02 | < 0.02 | < 0.02 | 13.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 249.7 | < 0.02 | < 0.02 | < 0.02 | 14.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 249.7 | < 0.02 | < 0.02 | 5.79 | 14.40 | 0.56 | 0.03 | 0.31 | 2.38 |
| 13 | 270.4 | < 0.02 | < 0.02 | 7.08 | 14.11 | 0.63 | 0.03 | 0.25 | 2.85 |
| 14 | 270.5 | < 0.02 | < 0.02 | < 0.02 | 14.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 300.5 | < 0.02 | < 0.02 | < 0.02 | 12.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 300.5 | 211.16 | 35.096 | 13.06 | 12.34 | 0.96 | < 0.02 | 0.03 | 4.61 |
| 9 | 320.2 | < 0.02 | < 0.02 | 13.26 | 12.20 | 0.97 | < 0.02 | 0.04 | 4.71 |
| 10 | 320.2 | < 0.02 | < 0.02 | < 0.02 | 12.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 348.7 | < 0.02 | < 0.02 | 13.29 | 11.92 | 0.97 | < 0.02 | 0.03 | 4.54 |
| 8 | 348.9 | < 0.02 | < 0.02 | < 0.02 | 11.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 399.9 | 216.92 | 34.933 | 15.16 | 11.24 | 1.09 | < 0.02 | 0.03 | 5.41 |
| 6 | 400 | < 0.02 | < 0.02 | < 0.02 | 11.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 429.6 | < 0.02 | < 0.02 | < 0.02 | 10.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 429.7 | < 0.02 | < 0.02 | 15.84 | 10.73 | 1.12 | < 0.02 | 0.03 | 5.63 |
| 1 | 466 | 219.55 | 34.876 | 15.90 | 10.67 | 1.13 | < 0.02 | 0.03 | 5.62 |
| 2 | 466.1 | < 0.02 | < 0.02 | < 0.02 | 10.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |