Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 50
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-20 06:05 to 2025-06-20 06:32 UTC
Where: 38° 12.4' S 149° 39.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.9 | 238.31 | 35.581 | 2.38 | 16.65 | 0.30 | < 0.02 | 0.32 | 1.01 |
| 35 | 4 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 16.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 49.4 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 49.4 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 49.4 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 49.4 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 49.5 | 237.37 | 35.575 | 2.46 | 16.58 | 0.30 | < 0.02 | 0.32 | 1.02 |
| 30 | 49.6 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 90.2 | < 0.02 | < 0.02 | < 0.02 | 16.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 16.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 90.4 | < 0.02 | < 0.02 | 3.07 | 16.54 | 0.34 | < 0.02 | 0.28 | 1.20 |
| 20 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 15.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 15.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 120.3 | < 0.02 | < 0.02 | 6.34 | 15.49 | 0.56 | < 0.02 | 0.09 | 2.28 |
| 17 | 160.9 | < 0.02 | < 0.02 | < 0.02 | 14.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 161 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 161 | < 0.02 | < 0.02 | 8.94 | 14.69 | 0.71 | < 0.02 | 0.05 | 3.03 |
| 13 | 180.1 | < 0.02 | < 0.02 | 9.62 | 14.10 | 0.76 | < 0.02 | 0.06 | 3.31 |
| 14 | 180.1 | < 0.02 | < 0.02 | < 0.02 | 14.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 180.3 | < 0.02 | < 0.02 | < 0.02 | 14.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 13.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 200.7 | < 0.02 | < 0.02 | 10.54 | 13.64 | 0.80 | < 0.02 | 0.04 | 3.61 |
| 11 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 13.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 250.7 | 211.87 | 35.228 | 10.97 | 13.29 | 0.83 | < 0.02 | 0.04 | 3.76 |
| 9 | 250.8 | < 0.02 | < 0.02 | < 0.02 | 13.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 250.8 | < 0.02 | < 0.02 | < 0.02 | 13.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 301 | < 0.02 | < 0.02 | < 0.02 | 12.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 301.1 | 211.83 | 35.127 | 12.52 | 12.54 | 0.92 | < 0.02 | 0.03 | 4.30 |
| 6 | 301.1 | < 0.02 | < 0.02 | < 0.02 | 12.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 374.9 | 212.54 | 35.002 | 14.56 | 11.52 | 1.05 | < 0.02 | 0.05 | 5.37 |
| 2 | 375 | < 0.02 | < 0.02 | < 0.02 | 11.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 375.2 | < 0.02 | < 0.02 | < 0.02 | 11.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |