Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 49
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-19 22:13 to 2025-06-19 22:48 UTC
Where: 38° 11.3' S 149° 46.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 22 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.2 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 4.2 | 238.40 | 35.562 | 2.50 | 16.41 | 0.30 | < 0.02 | 0.30 | 1.04 |
| 32 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.4 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 16.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 16.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 40.7 | < 0.02 | < 0.02 | 2.51 | 16.38 | 0.29 | < 0.02 | 0.30 | 1.04 |
| 17 | 79.2 | 240.01 | 35.556 | 2.51 | 16.39 | 0.30 | < 0.02 | 0.30 | 1.03 |
| 18 | 79.3 | < 0.02 | < 0.02 | < 0.02 | 16.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 139.8 | 235.45 | 35.537 | 2.97 | 16.35 | 0.33 | < 0.02 | 0.27 | 1.17 |
| 16 | 139.9 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 151.4 | < 0.02 | < 0.02 | 6.72 | 15.79 | 0.57 | < 0.02 | 0.07 | 2.22 |
| 14 | 151.5 | < 0.02 | < 0.02 | < 0.02 | 15.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 200.2 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 200.3 | 211.16 | 35.266 | 10.37 | 13.72 | 0.78 | < 0.02 | 0.02 | 3.39 |
| 9 | 250.2 | < 0.02 | < 0.02 | 12.01 | 12.88 | 0.89 | < 0.02 | 0.02 | 4.06 |
| 10 | 250.3 | < 0.02 | < 0.02 | < 0.02 | 12.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 278.8 | < 0.02 | < 0.02 | < 0.02 | 12.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 278.8 | 212.72 | 35.091 | 13.00 | 12.28 | 0.95 | < 0.02 | 0.02 | 4.49 |
| 5 | 331.6 | < 0.02 | < 0.02 | 14.96 | 11.26 | 1.07 | < 0.02 | 0.02 | 5.20 |
| 6 | 331.7 | < 0.02 | < 0.02 | < 0.02 | 11.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 339.4 | < 0.02 | < 0.02 | 15.06 | 11.13 | 1.08 | < 0.02 | 0.02 | 5.27 |
| 4 | 339.5 | < 0.02 | < 0.02 | < 0.02 | 11.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 388.1 | 216.47 | 34.937 | 15.20 | 11.09 | 1.09 | < 0.02 | 0.02 | 5.39 |
| 2 | 388.3 | < 0.02 | < 0.02 | < 0.02 | 11.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |