Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 33
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-12 09:32 to 2025-06-12 09:46 UTC
Where: 36° 48.0' S 150° 08.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 9.8 | < 0.02 | < 0.02 | < 0.02 | 17.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 17.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 10.8 | 226.74 | 35.571 | 3.01 | 17.85 | 0.32 | 0.04 | 0.32 | 1.59 |
| 31 | 24.9 | < 0.02 | < 0.02 | 3.18 | 17.71 | 0.34 | < 0.02 | 0.38 | 1.75 |
| 33 | 25 | < 0.02 | < 0.02 | < 0.02 | 17.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 25 | < 0.02 | < 0.02 | < 0.02 | 17.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 16.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 40.5 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 40.5 | < 0.02 | < 0.02 | 3.23 | 16.90 | 0.36 | 0.03 | 0.66 | 1.91 |
| 29 | 40.6 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 49.6 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 49.7 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 50.2 | 234.38 | 35.571 | 2.72 | 16.89 | 0.31 | 0.10 | 0.45 | 1.58 |
| 24 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 16.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 60 | < 0.02 | < 0.02 | 2.45 | 16.72 | 0.30 | 0.16 | 0.51 | 1.50 |
| 14 | 60 | < 0.02 | < 0.02 | < 0.02 | 16.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 16.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 60.1 | < 0.02 | < 0.02 | < 0.02 | 16.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 16.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 16.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 79.9 | 238.49 | 35.603 | 2.18 | 16.34 | 0.32 | 0.39 | 0.65 | 1.63 |
| 8 | 80 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 16.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 16.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 16.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 92.9 | < 0.02 | < 0.02 | < 0.02 | 16.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 93.1 | < 0.02 | < 0.02 | < 0.02 | 16.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 93.1 | 238.22 | 35.637 | 1.87 | 16.30 | 0.32 | 0.57 | 0.59 | 1.62 |
| 5 | 93.1 | < 0.02 | < 0.02 | < 0.02 | 16.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 93.2 | < 0.02 | < 0.02 | < 0.02 | 16.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 93.2 | < 0.02 | < 0.02 | < 0.02 | 16.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |