Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 30
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-12 03:18 to 2025-06-12 04:00 UTC
Where: 36° 48.8' S 150° 22.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 4.4 | 229.20 | 35.609 | 1.94 | 18.53 | 0.25 | < 0.02 | 0.28 | 1.06 |
| 36 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 18.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 18.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 18.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 18.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 19.9 | < 0.02 | < 0.02 | < 0.02 | 18.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 20 | < 0.02 | < 0.02 | 1.95 | 18.54 | 0.24 | 0.04 | 0.29 | 1.08 |
| 29 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 18.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 18.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 20.5 | < 0.02 | < 0.02 | < 0.02 | 18.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 16.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 70.6 | < 0.02 | < 0.02 | 2.90 | 16.86 | 0.32 | < 0.02 | 0.70 | 1.47 |
| 23 | 111.1 | < 0.02 | < 0.02 | 2.99 | 16.42 | 0.37 | 0.19 | 0.51 | 1.80 |
| 24 | 111.1 | < 0.02 | < 0.02 | < 0.02 | 16.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 150.6 | < 0.02 | < 0.02 | < 0.02 | 16.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 150.7 | 234.16 | 35.644 | 2.33 | 16.38 | 0.34 | 0.36 | 0.52 | 1.73 |
| 22 | 150.8 | < 0.02 | < 0.02 | < 0.02 | 16.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 150.8 | < 0.02 | < 0.02 | < 0.02 | 16.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 180.6 | < 0.02 | < 0.02 | 2.34 | 16.36 | 0.34 | 0.37 | 0.51 | 1.74 |
| 18 | 180.7 | < 0.02 | < 0.02 | < 0.02 | 16.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 221 | 230.63 | 35.604 | 3.36 | 16.09 | 0.39 | 0.27 | 0.42 | 1.96 |
| 16 | 221 | < 0.02 | < 0.02 | < 0.02 | 16.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 250.1 | 216.29 | 35.460 | 6.71 | 15.50 | 0.57 | 0.03 | 0.22 | 2.67 |
| 14 | 250.4 | < 0.02 | < 0.02 | < 0.02 | 15.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 269.9 | 202.27 | 35.239 | 11.04 | 13.97 | 0.81 | < 0.02 | 0.05 | 3.76 |
| 11 | 270.1 | < 0.02 | < 0.02 | < 0.02 | 13.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 310.4 | < 0.02 | < 0.02 | 12.11 | 12.90 | 0.87 | < 0.02 | 0.03 | 4.12 |
| 10 | 310.5 | < 0.02 | < 0.02 | < 0.02 | 12.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 360.6 | < 0.02 | < 0.02 | < 0.02 | 11.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 360.7 | 211.65 | 35.001 | 14.45 | 11.63 | 1.02 | < 0.02 | 0.02 | 5.10 |
| 5 | 419.6 | 211.69 | 34.932 | 15.55 | 11.22 | 1.09 | < 0.02 | 0.02 | 5.61 |
| 6 | 419.7 | < 0.02 | < 0.02 | < 0.02 | 11.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 479.9 | < 0.02 | < 0.02 | < 0.02 | 10.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 479.9 | < 0.02 | < 0.02 | 17.86 | 10.31 | 1.23 | < 0.02 | 0.02 | 6.96 |
| 2 | 541.8 | < 0.02 | < 0.02 | < 0.02 | 9.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 541.9 | 210.67 | 34.693 | 19.93 | 9.38 | 1.36 | < 0.02 | 0.02 | 8.54 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |