Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 22
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-08 01:25 to 2025-06-08 01:53 UTC
Where: 37° 07.9' S 150° 21.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 29 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 8.8 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 8.9 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 9 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 9.1 | 220.71 | 35.611 | 1.74 | 19.63 | 0.23 | < 0.02 | 0.25 | 0.93 |
| 32 | 9.1 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 9.2 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 9.2 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 21.4 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 21.5 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 21.6 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 21.7 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 21.7 | 220.45 | 35.611 | 1.77 | 19.63 | 0.23 | 0.03 | 0.24 | 0.91 |
| 22 | 21.8 | < 0.02 | < 0.02 | < 0.02 | 19.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 67.5 | < 0.02 | < 0.02 | < 0.02 | 19.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 67.6 | < 0.02 | < 0.02 | < 0.02 | 19.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 67.6 | 203.61 | 35.575 | 3.76 | 19.28 | 0.36 | < 0.02 | 0.16 | 1.35 |
| 16 | 126.7 | < 0.02 | < 0.02 | < 0.02 | 16.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 126.7 | < 0.02 | < 0.02 | < 0.02 | 16.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 126.9 | < 0.02 | < 0.02 | < 0.02 | 16.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 127.1 | < 0.02 | < 0.02 | < 0.02 | 16.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 127.2 | < 0.02 | < 0.02 | < 0.02 | 16.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 127.3 | 237.24 | 35.590 | 2.53 | 16.88 | 0.31 | 0.02 | 1.02 | 1.48 |
| 11 | 181.1 | < 0.02 | < 0.02 | < 0.02 | 16.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 181.1 | < 0.02 | < 0.02 | < 0.02 | 16.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 181.2 | 239.78 | 35.587 | 2.29 | 16.24 | 0.35 | 0.54 | 0.83 | 1.90 |
| 6 | 279.9 | 208.03 | 35.161 | 12.14 | 13.11 | 0.89 | < 0.02 | 0.05 | 4.10 |
| 7 | 280 | < 0.02 | < 0.02 | < 0.02 | 13.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 280.2 | < 0.02 | < 0.02 | < 0.02 | 13.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 325.2 | 212.68 | 35.070 | 13.57 | 12.24 | 0.97 | < 0.02 | 0.04 | 4.75 |
| 2 | 325.4 | < 0.02 | < 0.02 | < 0.02 | 12.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 325.5 | < 0.02 | < 0.02 | < 0.02 | 12.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 325.6 | < 0.02 | < 0.02 | < 0.02 | 12.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 325.7 | < 0.02 | < 0.02 | < 0.02 | 12.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |