Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 20
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-06 06:44 to 2025-06-06 07:13 UTC
Where: 38° 11.0' S 149° 39.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.7 | 238.04 | 35.590 | 1.56 | 17.25 | 0.22 | 0.02 | 0.27 | 0.89 |
| 27 | 25 | < 0.02 | < 0.02 | < 0.02 | 17.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 25 | < 0.02 | < 0.02 | 1.56 | 17.25 | 0.23 | 0.02 | 0.27 | 0.89 |
| 26 | 49.8 | 237.64 | 35.591 | 1.65 | 17.21 | 0.23 | 0.02 | 0.28 | 0.90 |
| 25 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 17.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 70.4 | < 0.02 | < 0.02 | 2.32 | 17.11 | 0.28 | < 0.02 | 0.29 | 1.13 |
| 23 | 70.5 | < 0.02 | < 0.02 | < 0.02 | 17.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 89.7 | < 0.02 | < 0.02 | 4.52 | 16.71 | 0.42 | < 0.02 | 0.16 | 1.72 |
| 21 | 89.9 | < 0.02 | < 0.02 | < 0.02 | 16.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 16.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 100 | < 0.02 | < 0.02 | 5.85 | 16.43 | 0.51 | < 0.02 | 0.09 | 2.10 |
| 18 | 119.9 | 197.09 | 35.370 | 9.14 | 15.32 | 0.71 | < 0.02 | < 0.02 | 3.07 |
| 17 | 120 | < 0.02 | < 0.02 | < 0.02 | 15.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 150.1 | < 0.02 | < 0.02 | < 0.02 | 14.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 150.3 | < 0.02 | < 0.02 | 9.81 | 14.58 | 0.75 | < 0.02 | < 0.02 | 3.29 |
| 13 | 170.3 | < 0.02 | < 0.02 | < 0.02 | 14.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 170.5 | < 0.02 | < 0.02 | 10.45 | 14.06 | 0.79 | < 0.02 | < 0.02 | 3.56 |
| 11 | 189.5 | < 0.02 | < 0.02 | < 0.02 | 13.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 189.5 | < 0.02 | < 0.02 | 10.61 | 13.89 | 0.79 | < 0.02 | < 0.02 | 3.61 |
| 9 | 200.1 | < 0.02 | < 0.02 | < 0.02 | 13.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 200.2 | < 0.02 | < 0.02 | 10.73 | 13.75 | 0.81 | < 0.02 | < 0.02 | 3.67 |
| 7 | 210.3 | < 0.02 | < 0.02 | < 0.02 | 13.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 210.5 | < 0.02 | < 0.02 | 10.89 | 13.49 | 0.81 | < 0.02 | < 0.02 | 3.69 |
| 5 | 240.1 | < 0.02 | < 0.02 | < 0.02 | 13.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 240.1 | < 0.02 | < 0.02 | 11.26 | 13.16 | 0.83 | < 0.02 | < 0.02 | 3.80 |
| 3 | 270.4 | < 0.02 | < 0.02 | < 0.02 | 12.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 270.6 | 211.25 | 35.177 | 11.80 | 12.98 | 0.86 | < 0.02 | < 0.02 | 4.07 |
| 1 | 296.6 | < 0.02 | < 0.02 | < 0.02 | 12.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 296.6 | 210.89 | 35.142 | 12.40 | 12.62 | 0.91 | < 0.02 | < 0.02 | 4.35 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |