Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-04 11:14 to 2025-06-04 11:56 UTC
Where: 38° 09.3' S 149° 24.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 5.8 | 238.98 | 35.606 | 1.53 | 17.24 | 0.23 | < 0.02 | 0.38 | 0.81 |
| 35 | 25 | < 0.02 | < 0.02 | 1.54 | 17.26 | 0.23 | < 0.02 | 0.38 | 0.83 |
| 33 | 59.5 | < 0.02 | < 0.02 | < 0.02 | 17.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 60 | < 0.02 | < 0.02 | 1.98 | 17.24 | 0.27 | < 0.02 | 0.49 | 1.02 |
| 31 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 17.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 80.2 | 235.81 | 35.640 | 2.21 | 17.20 | 0.29 | < 0.02 | 0.47 | 1.15 |
| 29 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 17.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 100.4 | < 0.02 | < 0.02 | 2.66 | 17.13 | 0.32 | < 0.02 | 0.47 | 1.26 |
| 28 | 109.9 | < 0.02 | < 0.02 | 5.80 | 16.44 | 0.52 | < 0.02 | 0.10 | 2.17 |
| 27 | 110.1 | < 0.02 | < 0.02 | < 0.02 | 16.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 120.4 | < 0.02 | < 0.02 | < 0.02 | 16.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 120.8 | < 0.02 | < 0.02 | 4.22 | 16.46 | 0.46 | 0.17 | 0.19 | 1.90 |
| 24 | 150.6 | 208.61 | 35.444 | 7.68 | 15.41 | 0.64 | < 0.02 | 0.10 | 2.78 |
| 23 | 150.7 | < 0.02 | < 0.02 | < 0.02 | 15.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 180.5 | < 0.02 | < 0.02 | < 0.02 | 15.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 180.6 | < 0.02 | < 0.02 | 8.72 | 14.99 | 0.70 | < 0.02 | 0.07 | 2.98 |
| 20 | 190.4 | < 0.02 | < 0.02 | 9.05 | 14.87 | 0.71 | < 0.02 | 0.06 | 3.08 |
| 19 | 190.4 | < 0.02 | < 0.02 | < 0.02 | 14.87 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 200.1 | < 0.02 | < 0.02 | < 0.02 | 14.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 200.5 | < 0.02 | < 0.02 | 9.84 | 14.28 | 0.76 | < 0.02 | 0.05 | 3.27 |
| 16 | 210.6 | < 0.02 | < 0.02 | 10.37 | 14.01 | 0.79 | < 0.02 | 0.04 | 3.44 |
| 15 | 210.8 | < 0.02 | < 0.02 | < 0.02 | 14.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 224.7 | < 0.02 | < 0.02 | 10.84 | 13.75 | 0.82 | < 0.02 | 0.04 | 3.64 |
| 13 | 225.3 | < 0.02 | < 0.02 | < 0.02 | 13.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 251.2 | 209.06 | 35.190 | 11.74 | 13.15 | 0.87 | < 0.02 | 0.05 | 4.02 |
| 11 | 251.3 | < 0.02 | < 0.02 | < 0.02 | 13.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 298.9 | < 0.02 | < 0.02 | < 0.02 | 12.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 299.4 | 210.04 | 35.100 | 13.17 | 12.42 | 0.96 | < 0.02 | 0.04 | 4.64 |
| 7 | 399.9 | < 0.02 | < 0.02 | < 0.02 | 11.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 400.3 | < 0.02 | < 0.02 | 15.19 | 11.50 | 1.09 | < 0.02 | 0.04 | 5.74 |
| 6 | 420.6 | < 0.02 | < 0.02 | 16.05 | 11.15 | 1.14 | < 0.02 | 0.02 | 6.23 |
| 5 | 420.8 | < 0.02 | < 0.02 | < 0.02 | 11.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 440.6 | 210.76 | 34.836 | 17.64 | 10.36 | 1.25 | < 0.02 | 0.02 | 7.35 |
| 3 | 440.9 | < 0.02 | < 0.02 | < 0.02 | 10.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 462.3 | 210.71 | 34.803 | 18.27 | 10.07 | 1.29 | < 0.02 | 0.03 | 7.87 |
| 1 | 462.6 | < 0.02 | < 0.02 | < 0.02 | 10.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |