Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 16
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-04 08:44 to 2025-06-04 09:29 UTC
Where: 38° 07.5' S 149° 25.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 7.9 | 238.94 | 35.604 | 1.56 | 17.27 | 0.23 | < 0.02 | 0.35 | 0.91 |
| 35 | 24.7 | < 0.02 | < 0.02 | 1.55 | 17.27 | 0.23 | < 0.02 | 0.35 | 0.92 |
| 34 | 60.5 | 233.76 | 35.625 | 2.72 | 17.11 | 0.32 | < 0.02 | 0.54 | 1.28 |
| 33 | 60.7 | < 0.02 | < 0.02 | < 0.02 | 17.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 80.1 | < 0.02 | < 0.02 | 4.11 | 16.78 | 0.41 | < 0.02 | 0.28 | 1.75 |
| 31 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 16.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 100.2 | < 0.02 | < 0.02 | 5.95 | 16.17 | 0.53 | < 0.02 | 0.17 | 2.30 |
| 27 | 120.5 | < 0.02 | < 0.02 | < 0.02 | 16.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 120.6 | < 0.02 | < 0.02 | 5.99 | 16.02 | 0.54 | 0.03 | 0.14 | 2.38 |
| 25 | 150.2 | < 0.02 | < 0.02 | < 0.02 | 15.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 150.7 | < 0.02 | < 0.02 | 8.30 | 15.28 | 0.67 | < 0.02 | 0.08 | 2.91 |
| 24 | 185 | 205.04 | 35.375 | 8.83 | 14.99 | 0.69 | < 0.02 | 0.08 | 3.05 |
| 23 | 185.3 | < 0.02 | < 0.02 | < 0.02 | 14.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 200.4 | < 0.02 | < 0.02 | < 0.02 | 14.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 200.6 | 205.08 | 35.367 | 8.95 | 14.92 | 0.70 | < 0.02 | 0.07 | 3.06 |
| 20 | 215.2 | < 0.02 | < 0.02 | 9.64 | 14.53 | 0.75 | < 0.02 | 0.05 | 3.28 |
| 19 | 215.2 | < 0.02 | < 0.02 | < 0.02 | 14.53 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 230.4 | < 0.02 | < 0.02 | 10.57 | 13.94 | 0.80 | < 0.02 | 0.05 | 3.60 |
| 17 | 230.4 | < 0.02 | < 0.02 | < 0.02 | 13.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 250.7 | < 0.02 | < 0.02 | < 0.02 | 13.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 250.7 | < 0.02 | < 0.02 | 11.27 | 13.61 | 0.84 | < 0.02 | 0.05 | 3.86 |
| 13 | 280.4 | < 0.02 | < 0.02 | < 0.02 | 12.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 280.6 | < 0.02 | < 0.02 | 12.54 | 12.88 | 0.92 | < 0.02 | 0.06 | 4.46 |
| 11 | 300.4 | < 0.02 | < 0.02 | < 0.02 | 12.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 300.7 | 207.94 | 35.104 | 13.26 | 12.47 | 0.96 | < 0.02 | 0.07 | 4.78 |
| 9 | 350.5 | < 0.02 | < 0.02 | < 0.02 | 11.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 350.7 | < 0.02 | < 0.02 | 14.20 | 11.94 | 1.03 | < 0.02 | 0.04 | 5.24 |
| 8 | 400.1 | < 0.02 | < 0.02 | 15.56 | 11.50 | 1.12 | < 0.02 | 0.06 | 6.27 |
| 7 | 400.6 | < 0.02 | < 0.02 | < 0.02 | 11.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 429.9 | < 0.02 | < 0.02 | < 0.02 | 11.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 430 | 208.70 | 34.919 | 16.45 | 11.03 | 1.18 | < 0.02 | 0.04 | 6.87 |
| 3 | 449.4 | < 0.02 | < 0.02 | < 0.02 | 10.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 449.6 | < 0.02 | < 0.02 | 16.86 | 10.88 | 1.21 | < 0.02 | 0.05 | 7.24 |
| 1 | 489.5 | < 0.02 | < 0.02 | < 0.02 | 9.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 490.4 | 209.42 | 34.827 | 18.14 | 9.92 | 1.28 | < 0.02 | 0.04 | 8.28 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |