Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-04 01:25 to 2025-06-04 01:40 UTC
Where: 37° 58.6' S 149° 05.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.8 | 241.44 | 35.840 | 1.16 | 16.58 | 0.32 | 0.21 | 0.36 | 1.28 |
| 33 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 16.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 22.8 | 241.17 | 35.840 | 1.18 | 16.59 | 0.33 | 0.21 | 0.37 | 1.29 |
| 26 | 23.2 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 23.3 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 23.9 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 24.6 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 49.9 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 50.4 | 240.95 | 35.841 | 1.19 | 16.59 | 0.32 | 0.21 | 0.38 | 1.27 |
| 23 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 59 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 59 | 240.59 | 35.843 | 1.23 | 16.60 | 0.33 | 0.20 | 0.41 | 1.28 |
| 16 | 59 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 59 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 59 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 59 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 80.1 | 240.72 | 35.842 | 1.23 | 16.60 | 0.32 | 0.20 | 0.40 | 1.29 |
| 8 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 80.6 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 101.4 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 101.5 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 101.5 | 240.95 | 35.841 | 1.22 | 16.60 | 0.33 | 0.21 | 0.40 | 1.27 |
| 3 | 101.5 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 101.7 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 101.7 | < 0.02 | < 0.02 | < 0.02 | 16.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |