Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 13
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-02 11:40 to 2025-06-02 12:23 UTC
Where: 38° 58.7' S 148° 38.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.5 | 235.59 | 35.611 | 1.21 | 17.77 | 0.20 | < 0.02 | 0.29 | 0.73 |
| 33 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 17.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 25 | 235.50 | 35.611 | 1.21 | 17.78 | 0.20 | < 0.02 | 0.30 | 0.73 |
| 28 | 50.4 | < 0.02 | < 0.02 | 1.28 | 17.78 | 0.20 | < 0.02 | 0.31 | 0.77 |
| 27 | 50.5 | < 0.02 | < 0.02 | < 0.02 | 17.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 100.2 | 231.39 | 35.602 | 1.71 | 17.74 | 0.23 | < 0.02 | 0.32 | 0.84 |
| 25 | 100.2 | < 0.02 | < 0.02 | < 0.02 | 17.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 120.5 | < 0.02 | < 0.02 | 7.35 | 16.53 | 0.59 | < 0.02 | 0.07 | 2.36 |
| 23 | 120.7 | < 0.02 | < 0.02 | < 0.02 | 16.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 140.5 | < 0.02 | < 0.02 | < 0.02 | 15.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 140.5 | 192.22 | 35.402 | 8.71 | 15.85 | 0.67 | < 0.02 | 0.04 | 2.73 |
| 19 | 160.4 | < 0.02 | < 0.02 | < 0.02 | 15.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 160.5 | < 0.02 | < 0.02 | 9.06 | 15.25 | 0.69 | < 0.02 | 0.03 | 2.86 |
| 17 | 180.6 | < 0.02 | < 0.02 | < 0.02 | 14.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 180.7 | < 0.02 | < 0.02 | 9.14 | 14.92 | 0.70 | < 0.02 | 0.02 | 2.92 |
| 15 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 14.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 200.7 | < 0.02 | < 0.02 | 9.25 | 14.66 | 0.71 | < 0.02 | 0.02 | 3.01 |
| 13 | 220.1 | < 0.02 | < 0.02 | < 0.02 | 14.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 220.1 | < 0.02 | < 0.02 | 9.39 | 14.34 | 0.71 | < 0.02 | 0.02 | 3.04 |
| 11 | 301 | < 0.02 | < 0.02 | < 0.02 | 13.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 301 | 213.57 | 35.213 | 11.01 | 13.27 | 0.82 | < 0.02 | 0.02 | 3.63 |
| 10 | 400.1 | 217.77 | 34.971 | 14.38 | 11.40 | 1.04 | < 0.02 | < 0.02 | 4.91 |
| 9 | 400.2 | < 0.02 | < 0.02 | < 0.02 | 11.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 449.5 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 449.6 | 224.33 | 34.861 | 15.59 | 10.64 | 1.11 | < 0.02 | 0.02 | 5.22 |
| 5 | 476.1 | < 0.02 | < 0.02 | < 0.02 | 10.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 476.3 | 226.30 | 34.808 | 16.32 | 10.26 | 1.16 | < 0.02 | < 0.02 | 5.45 |
| 3 | 499.6 | < 0.02 | < 0.02 | < 0.02 | 10.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 499.6 | 215.71 | 34.772 | 17.90 | 10.04 | 1.26 | < 0.02 | < 0.02 | 6.75 |
| 2 | 599.7 | 211.25 | 34.698 | 19.94 | 9.28 | 1.41 | < 0.02 | 0.02 | 9.40 |
| 1 | 599.7 | < 0.02 | < 0.02 | < 0.02 | 9.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |