Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-06-02 07:48 to 2025-06-02 08:34 UTC
Where: 39° 07.5' S 148° 40.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 17.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 17.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4.9 | 237.37 | 35.618 | 0.96 | 17.92 | 0.18 | < 0.02 | 0.26 | 0.71 |
| 31 | 25 | < 0.02 | < 0.02 | 1.00 | 17.91 | 0.18 | < 0.02 | 0.26 | 0.74 |
| 32 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 17.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 50.2 | 234.69 | 35.606 | 1.32 | 17.78 | 0.20 | < 0.02 | 0.29 | 0.78 |
| 30 | 50.3 | < 0.02 | < 0.02 | < 0.02 | 17.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 17.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 80.4 | < 0.02 | < 0.02 | 2.00 | 17.71 | 0.25 | 0.05 | 0.28 | 0.91 |
| 25 | 100.1 | 198.16 | 35.453 | 7.15 | 16.49 | 0.58 | < 0.02 | 0.07 | 2.30 |
| 26 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 16.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 140.8 | < 0.02 | < 0.02 | 8.94 | 15.65 | 0.69 | < 0.02 | 0.04 | 2.80 |
| 24 | 140.9 | < 0.02 | < 0.02 | < 0.02 | 15.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 190.8 | < 0.02 | < 0.02 | 9.41 | 14.76 | 0.73 | < 0.02 | 0.03 | 3.08 |
| 22 | 190.9 | < 0.02 | < 0.02 | < 0.02 | 14.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 220.1 | < 0.02 | < 0.02 | < 0.02 | 14.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 220.1 | < 0.02 | < 0.02 | 8.12 | 14.91 | 0.66 | < 0.02 | 0.08 | 2.84 |
| 17 | 240.7 | 210.49 | 35.399 | 8.30 | 14.84 | 0.66 | < 0.02 | 0.08 | 2.88 |
| 18 | 240.7 | < 0.02 | < 0.02 | < 0.02 | 14.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 260.9 | < 0.02 | < 0.02 | < 0.02 | 14.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 260.9 | < 0.02 | < 0.02 | 8.93 | 14.63 | 0.71 | < 0.02 | 0.06 | 3.08 |
| 13 | 350 | 211.51 | 35.056 | 13.68 | 12.06 | 1.00 | < 0.02 | 0.04 | 4.91 |
| 14 | 350 | < 0.02 | < 0.02 | < 0.02 | 12.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 440.5 | < 0.02 | < 0.02 | < 0.02 | 10.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 440.5 | 214.28 | 34.845 | 16.96 | 10.64 | 1.21 | < 0.02 | 0.02 | 6.50 |
| 10 | 480.2 | < 0.02 | < 0.02 | < 0.02 | 10.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 480.2 | < 0.02 | < 0.02 | 18.11 | 10.17 | 1.29 | < 0.02 | 0.03 | 7.59 |
| 7 | 523.8 | < 0.02 | < 0.02 | 19.68 | 9.56 | 1.39 | < 0.02 | 0.02 | 9.05 |
| 8 | 523.8 | < 0.02 | < 0.02 | < 0.02 | 9.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 560.2 | < 0.02 | < 0.02 | 21.02 | 9.06 | 1.48 | < 0.02 | 0.02 | 10.65 |
| 6 | 560.3 | < 0.02 | < 0.02 | < 0.02 | 9.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 580 | < 0.02 | < 0.02 | < 0.02 | 8.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 580.1 | 207.18 | 34.605 | 22.47 | 8.43 | 1.57 | < 0.02 | < 0.02 | 13.11 |
| 1 | 600.4 | 206.42 | 34.596 | 22.77 | 8.24 | 1.59 | < 0.02 | < 0.02 | 13.75 |
| 2 | 600.5 | < 0.02 | < 0.02 | < 0.02 | 8.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |