Please login if you have access to particular applications.
Deployment Details
Survey: - IN2025_V04 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 5
Gear: Autosal Salinometer,CDOM CTD 24 - SN 4367,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4664,Licor - CTD 24 - SN 70562,Oxygen CTD 24 - SN 3198,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1891,Temperature CTD 24 - SN 6285,Transmissometer - CTD 24 -CST-1735DR
When: 2025-05-30 06:34 to 2025-05-30 06:53 UTC
Where: 40° 35.9' S 148° 47.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.4 | 238.62 | 35.614 | 1.74 | 17.03 | 0.22 | 0.02 | 0.37 | 0.80 |
| 33 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 24 | < 0.02 | < 0.02 | < 0.02 | 17.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 24.1 | < 0.02 | < 0.02 | < 0.02 | 17.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 24.4 | < 0.02 | < 0.02 | < 0.02 | 17.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 24.4 | < 0.02 | < 0.02 | < 0.02 | 17.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 24.5 | 238.36 | 35.618 | 1.72 | 17.01 | 0.22 | < 0.02 | 0.38 | 0.81 |
| 27 | 24.5 | < 0.02 | < 0.02 | < 0.02 | 17.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 16.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 16.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 16.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 34.9 | < 0.02 | < 0.02 | < 0.02 | 16.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 35 | 238.22 | 35.621 | 1.73 | 16.98 | 0.23 | < 0.02 | 0.39 | 0.81 |
| 19 | 35.2 | < 0.02 | < 0.02 | < 0.02 | 16.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 59.2 | < 0.02 | < 0.02 | < 0.02 | 16.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 59.2 | < 0.02 | < 0.02 | < 0.02 | 16.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 59.3 | < 0.02 | < 0.02 | < 0.02 | 16.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 59.4 | < 0.02 | < 0.02 | < 0.02 | 16.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 59.5 | 236.66 | 35.619 | 1.94 | 16.95 | 0.24 | < 0.02 | 0.46 | 0.85 |
| 15 | 59.5 | < 0.02 | < 0.02 | < 0.02 | 16.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 79.7 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 79.8 | 235.01 | 35.611 | 2.23 | 16.91 | 0.26 | < 0.02 | 0.44 | 0.92 |
| 10 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 80 | < 0.02 | < 0.02 | < 0.02 | 16.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 152.7 | 234.87 | 35.604 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 152.8 | < 0.02 | < 0.02 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 152.8 | < 0.02 | < 0.02 | 2.47 | 16.69 | 0.29 | 0.06 | 0.38 | 1.04 |
| 4 | 152.9 | 234.74 | 35.604 | < 0.02 | 16.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 152.9 | < 0.02 | < 0.02 | < 0.02 | 16.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 153 | < 0.02 | < 0.02 | < 0.02 | 16.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72873 | Salinity (psu) |
| CDOM CTD 24 - SN 4367 | WET Labs | FLCDRTD | 4367 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4664 | Seabird | SBE4C | 4664 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24 - SN 3198 | Seabird | SBE43 | 3198 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBRTD | 6765 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1891 | Seabird | SBE SUNA | NTR1891 | Nitrate (µM) |
| Temperature CTD 24 - SN 6285 | Seabird | SBE3T | 6285 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1735DR | WET Labs | C-Star | CST-1735DR | Transmittance (%) |