Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 85
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-12-07 20:52 to 2023-12-07 22:48 UTC
Where: 55° 49.9' S 152° 24.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 8.4 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.5 | 340.14 | 33.874 | 27.53 | 2.59 | 1.89 | 0.30 | 0.23 | 17.00 |
| 33 | 29.8 | 340.18 | 33.880 | 27.50 | 2.58 | 1.88 | 0.31 | 0.23 | 17.01 |
| 34 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 2.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 60.2 | 340.76 | 33.879 | 27.58 | 2.52 | 1.89 | 0.31 | 0.23 | 17.29 |
| 32 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 2.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 90.6 | < 0.02 | < 0.02 | < 0.02 | 1.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 90.7 | 341.17 | 33.902 | 28.50 | 1.99 | 2.00 | 0.44 | 0.23 | 22.03 |
| 27 | 150.9 | 327.14 | 33.982 | 30.42 | 1.23 | 2.14 | 0.38 | 0.19 | 31.27 |
| 28 | 151 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 251.9 | 220.67 | 34.311 | 35.32 | 1.99 | 2.45 | 0.05 | 0.05 | 56.45 |
| 26 | 252 | < 0.02 | < 0.02 | < 0.02 | 2.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 350.9 | 193.16 | 34.453 | 35.93 | 2.13 | 2.49 | 0.05 | 0.03 | 67.82 |
| 24 | 351 | < 0.02 | < 0.02 | < 0.02 | 2.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 450.2 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 450.3 | 175.56 | 34.551 | 35.78 | 2.37 | 2.49 | 0.05 | 0.03 | 73.92 |
| 19 | 550.4 | 175.65 | 34.613 | 34.94 | 2.36 | 2.43 | 0.05 | 0.02 | 76.82 |
| 20 | 550.5 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 650.3 | 178.15 | 34.644 | 34.30 | 2.33 | 2.38 | 0.05 | 0.02 | 78.17 |
| 18 | 650.4 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 750.4 | 183.07 | 34.685 | 33.36 | 2.27 | 2.33 | 0.04 | 0.02 | 79.76 |
| 16 | 750.5 | < 0.02 | < 0.02 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 900.6 | 186.82 | 34.708 | 32.64 | 2.19 | 2.28 | 0.05 | 0.02 | 81.72 |
| 14 | 900.7 | < 0.02 | < 0.02 | < 0.02 | 2.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1050.3 | < 0.02 | < 0.02 | < 0.02 | 2.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1050.3 | 192.22 | 34.735 | 32.12 | 2.08 | 2.24 | 0.04 | 0.02 | 84.03 |
| 10 | 1200.3 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1200.3 | 196.33 | 34.735 | 31.78 | 1.95 | 2.21 | 0.05 | 0.02 | 87.12 |
| 8 | 1399.9 | < 0.02 | < 0.02 | < 0.02 | 1.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1400 | 199.72 | 34.739 | 31.77 | 1.78 | 2.22 | 0.04 | 0.02 | 92.03 |
| 5 | 1600.2 | 202.98 | 34.740 | 31.86 | 1.61 | 2.23 | 0.04 | < 0.02 | 97.16 |
| 6 | 1600.2 | < 0.02 | < 0.02 | < 0.02 | 1.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1799.9 | < 0.02 | < 0.02 | < 0.02 | 1.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1799.9 | 204.95 | 34.735 | 32.01 | 1.42 | 2.24 | 0.04 | < 0.02 | 102.46 |
| 2 | 2004.8 | < 0.02 | < 0.02 | < 0.02 | 1.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2004.8 | 206.87 | 34.732 | 32.26 | 1.27 | 2.26 | 0.04 | < 0.02 | 107.23 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |