Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 78
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-12-07 02:35 to 2023-12-07 05:11 UTC
Where: 55° 37.5' S 151° 50.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 3.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 10.2 | 341.57 | 33.824 | 25.92 | 3.13 | 1.71 | 0.12 | 0.26 | 8.10 |
| 33 | 31 | 341.92 | 33.826 | 25.92 | 3.09 | 1.73 | 0.14 | 0.26 | 8.14 |
| 34 | 31.1 | < 0.02 | < 0.02 | < 0.02 | 3.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 72.1 | 342.37 | 33.849 | 26.85 | 2.52 | 1.88 | 0.35 | 0.25 | 12.75 |
| 32 | 72.2 | < 0.02 | < 0.02 | < 0.02 | 2.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 131.3 | 335.18 | 33.849 | 27.65 | 1.78 | 1.95 | 0.33 | 0.22 | 14.31 |
| 28 | 171.5 | 318.88 | 33.916 | 29.05 | 1.83 | 2.03 | 0.16 | 0.14 | 19.17 |
| 29 | 171.7 | < 0.02 | < 0.02 | < 0.02 | 1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 252 | 248.23 | 34.162 | 32.79 | 2.64 | 2.27 | < 0.02 | 0.02 | 35.66 |
| 25 | 401 | 201.51 | 34.344 | 35.34 | 2.57 | 2.45 | < 0.02 | 0.02 | 55.11 |
| 26 | 401.4 | < 0.02 | < 0.02 | < 0.02 | 2.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 501.9 | 186.01 | 34.433 | 35.75 | 2.58 | 2.48 | < 0.02 | 0.02 | 62.96 |
| 22 | 602.5 | 178.87 | 34.506 | 35.60 | 2.57 | 2.48 | < 0.02 | 0.02 | 68.47 |
| 23 | 603.2 | < 0.02 | < 0.02 | < 0.02 | 2.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 753.5 | 175.07 | 34.596 | 34.98 | 2.44 | 2.43 | < 0.02 | 0.02 | 74.80 |
| 21 | 754.5 | < 0.02 | < 0.02 | < 0.02 | 2.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 900.8 | 180.12 | 34.655 | 33.82 | 2.38 | 2.35 | < 0.02 | 0.02 | 77.37 |
| 18 | 1000.6 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1000.7 | 183.29 | 34.684 | 33.07 | 2.35 | 2.31 | < 0.02 | < 0.02 | 78.22 |
| 16 | 1249.8 | 190.12 | 34.720 | 32.16 | 2.21 | 2.25 | < 0.02 | < 0.02 | 81.45 |
| 15 | 1500.6 | < 0.02 | < 0.02 | < 0.02 | 1.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1500.7 | 197.04 | 34.741 | 31.59 | 1.98 | 2.21 | < 0.02 | < 0.02 | 86.73 |
| 12 | 1749.1 | 200.48 | 34.742 | 31.64 | 1.71 | 2.21 | < 0.02 | < 0.02 | 93.88 |
| 13 | 1749.2 | < 0.02 | < 0.02 | < 0.02 | 1.71 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2001 | 203.79 | 34.738 | 31.82 | 1.52 | 2.22 | < 0.02 | < 0.02 | 99.52 |
| 10 | 2200.3 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 2200.4 | 207.00 | 34.731 | 32.05 | 1.32 | 2.24 | < 0.02 | < 0.02 | 105.27 |
| 8 | 2500.1 | 209.42 | 34.718 | 32.58 | 1.07 | 2.28 | < 0.02 | < 0.02 | 114.94 |
| 6 | 2800.6 | 213.03 | 34.708 | 32.87 | 0.88 | 2.31 | < 0.02 | < 0.02 | 121.45 |
| 7 | 2800.6 | < 0.02 | < 0.02 | < 0.02 | 0.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 3000.6 | 213.61 | 34.707 | 32.94 | 0.85 | 2.31 | < 0.02 | < 0.02 | 122.52 |
| 3 | 3301.8 | 215.98 | 34.699 | 33.07 | 0.73 | 2.32 | < 0.02 | < 0.02 | 125.65 |
| 4 | 3301.9 | < 0.02 | < 0.02 | < 0.02 | 0.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 3364.9 | 216.74 | 34.697 | 33.08 | 0.69 | 2.32 | < 0.02 | < 0.02 | 126.57 |
| 2 | 3365.1 | < 0.02 | < 0.02 | < 0.02 | 0.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |