Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 39
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-11-27 01:38 to 2023-11-27 03:34 UTC
Where: 55° 58.4' S 152° 06.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 10.3 | 342.91 | 33.894 | 27.89 | 2.31 | 1.92 | 0.17 | 0.22 | 20.91 |
| 36 | 10.4 | < 0.02 | < 0.02 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 29.8 | 343.85 | 33.901 | 28.04 | 2.25 | 1.93 | 0.17 | 0.23 | 22.09 |
| 34 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 2.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 45.1 | < 0.02 | < 0.02 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 45.2 | 344.74 | 33.909 | 28.21 | 2.15 | 1.94 | 0.18 | 0.23 | 23.55 |
| 29 | 60.2 | 344.56 | 33.911 | 28.29 | 2.09 | 1.97 | 0.24 | 0.23 | 23.87 |
| 30 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 2.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 75.2 | 342.95 | 33.931 | 28.81 | 1.72 | 2.01 | 0.32 | 0.22 | 26.72 |
| 28 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 1.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 105 | < 0.02 | < 0.02 | < 0.02 | 0.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 105.1 | 327.77 | 34.022 | 30.80 | 0.99 | 2.17 | 0.32 | 0.18 | 36.15 |
| 23 | 249.9 | 208.92 | 34.357 | 35.53 | 2.02 | 2.48 | < 0.02 | 0.03 | 60.89 |
| 24 | 249.9 | < 0.02 | < 0.02 | < 0.02 | 1.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 351.2 | 176.32 | 34.507 | 36.02 | 2.33 | 2.51 | < 0.02 | < 0.02 | 71.89 |
| 22 | 351.5 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 450.7 | 173.51 | 34.556 | 35.82 | 2.23 | 2.49 | < 0.02 | < 0.02 | 76.32 |
| 20 | 450.9 | < 0.02 | < 0.02 | < 0.02 | 2.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 601.2 | 175.47 | 34.639 | 34.38 | 2.28 | 2.40 | < 0.02 | < 0.02 | 79.42 |
| 18 | 601.4 | < 0.02 | < 0.02 | < 0.02 | 2.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 750.4 | 182.13 | 34.689 | 33.05 | 2.24 | 2.32 | < 0.02 | < 0.02 | 80.86 |
| 16 | 750.7 | < 0.02 | < 0.02 | < 0.02 | 2.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 901.1 | 187.93 | 34.718 | 32.27 | 2.12 | 2.26 | < 0.02 | < 0.02 | 83.74 |
| 14 | 901.3 | < 0.02 | < 0.02 | < 0.02 | 2.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1049.9 | 191.77 | 34.732 | 31.86 | 2.04 | 2.23 | < 0.02 | < 0.02 | 85.65 |
| 12 | 1049.9 | < 0.02 | < 0.02 | < 0.02 | 2.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 1199.6 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 1199.6 | 194.50 | 34.739 | 31.68 | 1.95 | 2.22 | < 0.02 | < 0.02 | 87.83 |
| 8 | 1391.2 | < 0.02 | < 0.02 | < 0.02 | 1.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1391.2 | 198.25 | 34.741 | 31.58 | 1.76 | 2.22 | < 0.02 | < 0.02 | 92.78 |
| 5 | 1601 | 201.96 | 34.740 | 31.66 | 1.58 | 2.23 | < 0.02 | < 0.02 | 99.00 |
| 6 | 1601.3 | < 0.02 | < 0.02 | < 0.02 | 1.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1802 | 202.98 | 34.735 | 31.97 | 1.43 | 2.25 | < 0.02 | < 0.02 | 104.71 |
| 4 | 1802.5 | < 0.02 | < 0.02 | < 0.02 | 1.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1999.7 | < 0.02 | < 0.02 | < 0.02 | 1.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1999.9 | 205.71 | 34.726 | 32.25 | 1.22 | 2.28 | < 0.02 | < 0.02 | 110.73 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |