Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 24
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-11-24 04:19 to 2023-11-24 05:26 UTC
Where: 55° 00.0' S 152° 08.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 9.5 | < 0.02 | < 0.02 | < 0.02 | 3.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 9.6 | 332.14 | 33.859 | 25.23 | 3.52 | 1.76 | 0.21 | 0.21 | 9.10 |
| 36 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 3.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 34.7 | 332.77 | 33.857 | 25.24 | 3.45 | 1.76 | 0.20 | 0.21 | 9.12 |
| 31 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 3.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 35 | < 0.02 | < 0.02 | < 0.02 | 3.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 59.3 | < 0.02 | < 0.02 | < 0.02 | 3.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 59.7 | 332.95 | 33.853 | 25.32 | 3.37 | 1.77 | 0.19 | 0.21 | 9.17 |
| 30 | 59.9 | < 0.02 | < 0.02 | < 0.02 | 3.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 130.5 | < 0.02 | < 0.02 | < 0.02 | 3.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 130.6 | 328.75 | 33.866 | 25.71 | 3.15 | 1.81 | 0.37 | 0.21 | 10.21 |
| 27 | 131.1 | < 0.02 | < 0.02 | < 0.02 | 3.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 179.1 | < 0.02 | < 0.02 | < 0.02 | 2.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 180.3 | 328.97 | 33.862 | 26.97 | 2.30 | 1.91 | 0.31 | 0.21 | 13.00 |
| 24 | 180.9 | < 0.02 | < 0.02 | < 0.02 | 2.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 350.7 | < 0.02 | < 0.02 | < 0.02 | 3.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 351.1 | 233.93 | 34.213 | 32.49 | 3.04 | 2.25 | 0.07 | < 0.02 | 36.68 |
| 21 | 351.5 | < 0.02 | < 0.02 | < 0.02 | 3.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 460.2 | < 0.02 | < 0.02 | < 0.02 | 3.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 460.6 | 204.68 | 34.329 | 34.11 | 3.01 | 2.37 | 0.07 | < 0.02 | 48.64 |
| 18 | 460.7 | < 0.02 | < 0.02 | < 0.02 | 3.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 599.6 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 599.8 | 189.01 | 34.414 | 34.93 | 2.76 | 2.45 | 0.07 | < 0.02 | 59.47 |
| 15 | 600.1 | < 0.02 | < 0.02 | < 0.02 | 2.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 749.6 | < 0.02 | < 0.02 | < 0.02 | 2.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 749.8 | 178.51 | 34.509 | 35.03 | 2.63 | 2.45 | 0.07 | < 0.02 | 68.25 |
| 12 | 750.5 | < 0.02 | < 0.02 | < 0.02 | 2.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 899.1 | < 0.02 | < 0.02 | < 0.02 | 2.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 899.7 | 176.14 | 34.586 | 34.28 | 2.58 | 2.40 | 0.07 | < 0.02 | 72.96 |
| 9 | 900 | < 0.02 | < 0.02 | < 0.02 | 2.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1050.1 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1050.4 | 178.64 | 34.634 | 33.66 | 2.46 | 2.36 | 0.07 | < 0.02 | 75.76 |
| 6 | 1050.9 | < 0.02 | < 0.02 | < 0.02 | 2.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1200.8 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1200.9 | 253.72 | 34.684 | 32.70 | 2.37 | 2.29 | 0.07 | < 0.02 | 78.46 |
| 1 | 1201.1 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |