Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 17
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-11-21 23:28 to 2023-11-22 02:49 UTC
Where: 55° 26.2' S 151° 43.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 2.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.2 | 341.84 | 33.840 | 27.25 | 2.30 | 1.87 | 0.15 | 0.22 | 14.25 |
| 34 | 35.5 | < 0.02 | < 0.02 | < 0.02 | 2.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 35.6 | 342.37 | 33.849 | 27.49 | 2.17 | 1.90 | 0.16 | 0.22 | 15.75 |
| 32 | 81.8 | < 0.02 | < 0.02 | < 0.02 | 2.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 81.9 | 342.33 | 33.862 | 27.93 | 2.02 | 1.94 | 0.19 | 0.21 | 18.13 |
| 29 | 167.9 | 325.49 | 33.942 | 29.85 | 1.58 | 2.08 | 0.19 | 0.14 | 26.02 |
| 30 | 168 | < 0.02 | < 0.02 | < 0.02 | 1.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 242.2 | 236.93 | 34.197 | 33.83 | 2.41 | 2.34 | 0.04 | < 0.02 | 42.44 |
| 27 | 301.3 | 216.29 | 34.277 | 35.67 | 2.53 | 2.47 | 0.04 | < 0.02 | 61.94 |
| 25 | 420.8 | 188.02 | 34.419 | 35.65 | 2.60 | 2.48 | 0.04 | < 0.02 | 61.96 |
| 26 | 421.3 | < 0.02 | < 0.02 | < 0.02 | 2.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 541 | 176.68 | 34.502 | 35.89 | 2.51 | 2.49 | 0.04 | < 0.02 | 69.73 |
| 22 | 660.7 | 175.16 | 34.574 | 35.14 | 2.48 | 2.44 | 0.03 | < 0.02 | 73.44 |
| 23 | 660.7 | < 0.02 | < 0.02 | < 0.02 | 2.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 779.6 | 176.86 | 34.628 | 34.27 | 2.43 | 2.39 | 0.03 | < 0.02 | 76.30 |
| 20 | 871.8 | < 0.02 | < 0.02 | < 0.02 | 2.35 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 874.7 | 178.02 | 34.654 | 33.93 | 2.35 | 2.37 | 0.03 | < 0.02 | 78.46 |
| 17 | 1000.5 | 181.46 | 34.685 | 33.44 | 2.26 | 2.32 | 0.03 | < 0.02 | 80.87 |
| 18 | 1000.5 | < 0.02 | < 0.02 | < 0.02 | 2.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1201.6 | 189.45 | 34.722 | 32.31 | 2.12 | 2.25 | 0.03 | < 0.02 | 83.63 |
| 15 | 1401.2 | 196.11 | 34.739 | 31.68 | 1.96 | 2.20 | 0.03 | < 0.02 | 87.63 |
| 13 | 1600.6 | 199.01 | 34.743 | 31.70 | 1.80 | 2.21 | 0.03 | < 0.02 | 91.86 |
| 14 | 1600.6 | < 0.02 | < 0.02 | < 0.02 | 1.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1832 | 202.58 | 34.739 | 31.80 | 1.59 | 2.22 | 0.03 | < 0.02 | 98.25 |
| 11 | 2051.7 | 204.23 | 34.734 | 32.15 | 1.41 | 2.24 | 0.03 | < 0.02 | 105.53 |
| 10 | 2299.9 | 207.14 | 34.723 | 32.54 | 1.15 | 2.28 | 0.03 | < 0.02 | 113.60 |
| 8 | 2549.8 | 209.55 | 34.716 | 32.82 | 1.01 | 2.30 | 0.03 | < 0.02 | 118.47 |
| 9 | 2550.3 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 2799.1 | 212.23 | 34.708 | 32.98 | 0.88 | 2.30 | 0.03 | < 0.02 | 121.92 |
| 6 | 3101 | 213.79 | 34.702 | 33.03 | 0.84 | 2.31 | 0.03 | < 0.02 | 123.76 |
| 5 | 3448.1 | 216.83 | 34.700 | 33.16 | 0.69 | 2.32 | 0.03 | < 0.02 | 127.37 |
| 4 | 3610 | < 0.02 | < 0.02 | < 0.02 | 0.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 3610.6 | 218.88 | 34.693 | 33.22 | 0.61 | 2.33 | 0.04 | < 0.02 | 129.55 |
| 1 | 3677.7 | 220.13 | 34.689 | 33.29 | 0.57 | 2.33 | 0.03 | < 0.02 | 130.35 |
| 2 | 3677.9 | < 0.02 | < 0.02 | < 0.02 | 0.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |