Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V07 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 15
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4773,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Seabird SBE SUNA - SN NTR1890,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-11-21 18:21 to 2023-11-21 19:36 UTC
Where: 55° 33.8' S 151° 48.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 25.1 | < 0.02 | < 0.02 | < 0.02 | 1.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 25.2 | 342.15 | 33.888 | 28.61 | 1.96 | 1.95 | 0.17 | 0.21 | 21.88 |
| 33 | 25.7 | < 0.02 | < 0.02 | < 0.02 | 1.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 50.4 | 342.64 | 33.893 | 28.71 | 1.88 | 1.97 | 0.20 | 0.22 | 22.73 |
| 28 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 50.6 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 160.4 | < 0.02 | < 0.02 | < 0.02 | 1.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 160.4 | 342.06 | 33.920 | 29.55 | 1.03 | 2.06 | 0.34 | 0.19 | 25.60 |
| 27 | 160.7 | < 0.02 | < 0.02 | < 0.02 | 1.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 201.1 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 201.2 | < 0.02 | < 0.02 | < 0.02 | 1.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 201.5 | 252.83 | 34.154 | 33.63 | 1.90 | 2.32 | < 0.02 | < 0.02 | 42.26 |
| 19 | 351.1 | < 0.02 | < 0.02 | < 0.02 | 2.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 351.3 | 184.58 | 34.434 | 36.13 | 2.51 | 2.50 | < 0.02 | < 0.02 | 65.34 |
| 21 | 352.2 | < 0.02 | < 0.02 | < 0.02 | 2.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 500.9 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 501.2 | < 0.02 | < 0.02 | < 0.02 | 2.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 501.3 | 173.20 | 34.546 | 35.99 | 2.37 | 2.49 | < 0.02 | < 0.02 | 75.14 |
| 13 | 599.9 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 600.2 | 174.13 | 34.601 | 35.17 | 2.36 | 2.43 | < 0.02 | < 0.02 | 77.44 |
| 15 | 600.5 | < 0.02 | < 0.02 | < 0.02 | 2.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 750.7 | < 0.02 | < 0.02 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 750.8 | 177.48 | 34.659 | 34.11 | 2.27 | 2.36 | < 0.02 | < 0.02 | 80.72 |
| 12 | 751.2 | < 0.02 | < 0.02 | < 0.02 | 2.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 900.6 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 900.8 | 183.60 | 34.694 | 33.15 | 2.22 | 2.29 | < 0.02 | < 0.02 | 81.55 |
| 7 | 901.1 | < 0.02 | < 0.02 | < 0.02 | 2.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1049.8 | < 0.02 | < 0.02 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1049.8 | 190.35 | 34.723 | 32.09 | 2.15 | 2.22 | < 0.02 | < 0.02 | 82.77 |
| 6 | 1050 | < 0.02 | < 0.02 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 1201.3 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1201.5 | < 0.02 | < 0.02 | < 0.02 | 2.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1201.6 | 194.45 | 34.735 | 31.81 | 2.01 | 2.21 | < 0.02 | < 0.02 | 86.91 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4773 | Seabird | SBE4C | 4773 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Seabird SBE SUNA - SN NTR1890 | Seabird | SBE SUNA | NTR1890 | Nitrate (µM) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |