Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 83
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-31 05:19 to 2023-10-31 07:23 UTC
Where: 33° 27.9' S 152° 47.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.6 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 7.9 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 8.5 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 21.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 9 | 230.14 | 35.580 | 0.03 | 21.79 | 0.10 | < 0.02 | 0.02 | 0.04 |
| 28 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 60.5 | 229.96 | 35.670 | 0.06 | 20.33 | 0.11 | 0.05 | 0.03 | 0.35 |
| 26 | 60.9 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 61.2 | < 0.02 | < 0.02 | < 0.02 | 20.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 125.4 | < 0.02 | < 0.02 | < 0.02 | 18.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 125.8 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 125.9 | < 0.02 | < 0.02 | < 0.02 | 18.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 125.9 | < 0.02 | < 0.02 | < 0.02 | 18.85 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 126.2 | 218.17 | 35.634 | 2.00 | 18.84 | 0.23 | < 0.02 | 0.50 | 0.88 |
| 15 | 249.1 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 249.3 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 249.6 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 249.7 | < 0.02 | < 0.02 | < 0.02 | 17.31 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 249.7 | 197.49 | 35.538 | 6.15 | 17.31 | 0.50 | < 0.02 | 0.02 | 1.88 |
| 9 | 503.1 | < 0.02 | < 0.02 | < 0.02 | 12.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 503.4 | < 0.02 | < 0.02 | < 0.02 | 12.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 503.5 | < 0.02 | < 0.02 | < 0.02 | 12.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 503.6 | < 0.02 | < 0.02 | < 0.02 | 12.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 503.7 | 201.33 | 35.028 | 14.36 | 12.03 | 1.02 | < 0.02 | < 0.02 | 5.07 |
| 8 | 1002.1 | 196.06 | 34.440 | 28.30 | 5.87 | 1.98 | < 0.02 | < 0.02 | 29.59 |
| 7 | 1204 | < 0.02 | < 0.02 | 31.72 | 4.55 | 2.23 | < 0.02 | < 0.02 | 52.89 |
| 6 | 1404 | < 0.02 | < 0.02 | 33.80 | 3.65 | 2.41 | < 0.02 | < 0.02 | 75.58 |
| 5 | 1594.1 | < 0.02 | < 0.02 | 34.72 | 3.13 | 2.48 | < 0.02 | < 0.02 | 88.68 |
| 4 | 1800.3 | < 0.02 | < 0.02 | 34.78 | 2.70 | 2.49 | < 0.02 | < 0.02 | 95.65 |
| 3 | 2001.9 | 165.34 | 34.651 | 34.19 | 2.44 | 2.43 | < 0.02 | < 0.02 | 95.93 |
| 2 | 2499 | < 0.02 | < 0.02 | 32.76 | 2.03 | 2.31 | < 0.02 | < 0.02 | 96.85 |
| 1 | 3000.5 | 193.11 | 34.726 | 32.43 | 1.64 | 2.27 | < 0.02 | < 0.02 | 105.60 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |