Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 79
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-29 03:57 to 2023-10-29 06:08 UTC
Where: 32° 33.7' S 154° 26.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 21.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 21.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 21.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7 | < 0.02 | < 0.02 | < 0.02 | 21.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 21.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.9 | 222.90 | 35.531 | 0.36 | 21.74 | 0.16 | 0.11 | 0.11 | 0.50 |
| 30 | 15.3 | < 0.02 | < 0.02 | < 0.02 | 21.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 15 | < 0.02 | < 0.02 | 0.38 | 21.65 | 0.16 | 0.08 | 0.13 | 0.49 |
| 28 | 30.6 | < 0.02 | < 0.02 | < 0.02 | 21.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 30.1 | 222.86 | 35.526 | 0.40 | 21.63 | 0.16 | 0.09 | 0.13 | 0.48 |
| 26 | 60 | < 0.02 | < 0.02 | < 0.02 | 21.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.3 | < 0.02 | < 0.02 | 0.46 | 21.62 | 0.15 | 0.10 | 0.15 | 0.52 |
| 24 | 90 | < 0.02 | < 0.02 | < 0.02 | 21.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 90 | 220.00 | 35.526 | 0.46 | 21.62 | 0.17 | 0.12 | 0.15 | 0.52 |
| 22 | 125.2 | < 0.02 | < 0.02 | < 0.02 | 20.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 125.3 | 196.55 | 35.612 | 3.34 | 20.46 | 0.33 | < 0.02 | 0.04 | 1.06 |
| 20 | 150.5 | < 0.02 | < 0.02 | 2.54 | 19.96 | 0.27 | < 0.02 | 0.04 | 0.90 |
| 19 | 200 | 216.16 | 35.631 | 2.22 | 19.21 | 0.25 | < 0.02 | 0.04 | 0.87 |
| 18 | 249.8 | < 0.02 | < 0.02 | 3.91 | 18.43 | 0.35 | < 0.02 | 0.03 | 1.22 |
| 17 | 300.3 | 219.64 | 35.625 | 3.22 | 18.05 | 0.31 | < 0.02 | 0.03 | 1.07 |
| 16 | 350.3 | < 0.02 | < 0.02 | 5.24 | 17.40 | 0.44 | < 0.02 | 0.03 | 1.55 |
| 15 | 400.8 | < 0.02 | < 0.02 | 8.22 | 16.63 | 0.62 | < 0.02 | 0.03 | 2.38 |
| 14 | 499.5 | 198.83 | 35.280 | 10.49 | 14.46 | 0.77 | < 0.02 | 0.02 | 3.26 |
| 13 | 600.4 | < 0.02 | < 0.02 | 15.82 | 11.77 | 1.11 | < 0.02 | 0.02 | 5.53 |
| 12 | 700.9 | 203.03 | 34.751 | 19.50 | 10.05 | 1.34 | < 0.02 | 0.02 | 7.92 |
| 11 | 801.1 | < 0.02 | < 0.02 | 22.43 | 8.69 | 1.53 | < 0.02 | 0.02 | 10.79 |
| 10 | 900.2 | < 0.02 | < 0.02 | 25.40 | 7.45 | 1.72 | < 0.02 | < 0.02 | 16.11 |
| 9 | 1000.3 | 202.45 | 34.467 | 27.13 | 6.77 | 1.85 | < 0.02 | < 0.02 | 21.50 |
| 8 | 1100.7 | < 0.02 | < 0.02 | 29.41 | 5.86 | 2.02 | < 0.02 | < 0.02 | 30.60 |
| 7 | 1200.5 | < 0.02 | < 0.02 | 31.34 | 5.08 | 2.16 | < 0.02 | < 0.02 | 42.15 |
| 6 | 1399.8 | < 0.02 | < 0.02 | 33.55 | 4.13 | 2.35 | < 0.02 | < 0.02 | 62.99 |
| 5 | 1600.4 | 160.20 | 34.551 | 35.21 | 3.35 | 2.48 | < 0.02 | < 0.02 | 82.62 |
| 4 | 1800.8 | < 0.02 | < 0.02 | 35.46 | 2.85 | 2.50 | < 0.02 | < 0.02 | 91.81 |
| 3 | 2000.4 | 163.24 | 34.637 | 35.06 | 2.54 | 2.47 | < 0.02 | < 0.02 | 94.70 |
| 2 | 2501.4 | < 0.02 | < 0.02 | 33.24 | 2.03 | 2.33 | < 0.02 | 0.02 | 96.90 |
| 1 | 3002.2 | 192.98 | 34.724 | 33.01 | 1.65 | 2.30 | < 0.02 | 0.02 | 105.92 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |