Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 71
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-27 16:11 to 2023-10-27 18:44 UTC
Where: 33° 39.5' S 155° 27.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 4.8 | 225.05 | 35.540 | 0.09 | 21.29 | 0.15 | 0.09 | 0.04 | 0.46 |
| 35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 21.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 21.30 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 30.7 | 225.00 | 35.541 | 0.09 | 21.30 | 0.14 | 0.08 | 0.04 | 0.44 |
| 28 | 49.5 | < 0.02 | < 0.02 | 0.57 | 21.10 | 0.17 | 0.23 | 0.17 | 0.51 |
| 29 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 21.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 70 | 211.43 | 35.582 | 1.86 | 20.55 | 0.24 | 0.04 | 0.42 | 0.79 |
| 26 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 20.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 99.6 | 191.82 | 35.620 | 4.49 | 19.42 | 0.40 | < 0.02 | 0.04 | 1.46 |
| 25 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 19.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 124.9 | < 0.02 | < 0.02 | < 0.02 | 18.88 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 124.9 | < 0.02 | < 0.02 | 4.09 | 18.88 | 0.37 | < 0.02 | 0.04 | 1.34 |
| 21 | 150.1 | < 0.02 | < 0.02 | 4.75 | 18.41 | 0.40 | < 0.02 | 0.02 | 1.49 |
| 20 | 174.9 | < 0.02 | < 0.02 | 4.55 | 18.21 | 0.39 | < 0.02 | 0.02 | 1.49 |
| 19 | 200 | 209.33 | 35.595 | 4.43 | 17.82 | 0.39 | < 0.02 | 0.02 | 1.53 |
| 18 | 224.9 | < 0.02 | < 0.02 | 4.77 | 17.57 | 0.41 | < 0.02 | 0.02 | 1.61 |
| 17 | 251.1 | < 0.02 | < 0.02 | 7.23 | 17.05 | 0.56 | < 0.02 | 0.02 | 2.24 |
| 16 | 299.8 | 199.01 | 35.445 | 7.71 | 16.11 | 0.60 | < 0.02 | 0.02 | 2.43 |
| 15 | 350.6 | < 0.02 | < 0.02 | 8.93 | 15.16 | 0.67 | < 0.02 | 0.02 | 2.89 |
| 14 | 400.8 | < 0.02 | < 0.02 | 11.82 | 13.73 | 0.86 | < 0.02 | 0.02 | 3.96 |
| 13 | 501.2 | < 0.02 | < 0.02 | 14.31 | 12.45 | 1.00 | < 0.02 | 0.02 | 4.89 |
| 12 | 600.1 | 199.68 | 34.958 | 15.98 | 11.59 | 1.10 | < 0.02 | 0.02 | 5.79 |
| 11 | 700.5 | < 0.02 | < 0.02 | 17.56 | 10.87 | 1.20 | < 0.02 | < 0.02 | 6.68 |
| 10 | 799.9 | < 0.02 | < 0.02 | 23.01 | 8.31 | 1.55 | < 0.02 | < 0.02 | 12.02 |
| 9 | 900.9 | < 0.02 | < 0.02 | 25.01 | 7.39 | 1.70 | < 0.02 | < 0.02 | 15.93 |
| 8 | 1000.1 | 204.73 | 34.448 | 27.13 | 6.58 | 1.84 | < 0.02 | < 0.02 | 21.82 |
| 7 | 1201.6 | < 0.02 | < 0.02 | 30.52 | 5.31 | 2.09 | < 0.02 | < 0.02 | 38.51 |
| 6 | 1400.6 | 176.19 | 34.479 | 32.90 | 4.36 | 2.28 | < 0.02 | < 0.02 | 58.68 |
| 5 | 1599.8 | < 0.02 | < 0.02 | 34.76 | 3.55 | 2.42 | < 0.02 | < 0.02 | 79.87 |
| 4 | 1800.6 | < 0.02 | < 0.02 | 35.57 | 2.95 | 2.49 | < 0.02 | < 0.02 | 92.71 |
| 3 | 2001 | 161.85 | 34.629 | 35.20 | 2.60 | 2.45 | < 0.02 | < 0.02 | 95.20 |
| 2 | 2502 | 182.75 | 34.705 | 33.37 | 2.08 | 2.31 | < 0.02 | 0.02 | 96.61 |
| 1 | 3002 | 193.16 | 34.726 | 32.91 | 1.68 | 2.28 | < 0.02 | 0.02 | 105.56 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |