Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 70
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-27 10:49 to 2023-10-27 13:32 UTC
Where: 33° 50.8' S 155° 47.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 7 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.6 | 222.68 | 35.509 | 0.13 | 21.83 | 0.14 | 0.07 | 0.04 | 0.52 |
| 30 | 30 | < 0.02 | < 0.02 | < 0.02 | 21.83 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 30.1 | 222.81 | 35.509 | 0.13 | 21.83 | 0.14 | 0.06 | 0.04 | 0.53 |
| 28 | 70.3 | < 0.02 | < 0.02 | < 0.02 | 21.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 70.6 | 222.01 | 35.512 | 0.20 | 21.72 | 0.15 | 0.09 | 0.05 | 0.49 |
| 25 | 99.4 | 200.66 | 35.590 | 2.89 | 20.59 | 0.31 | < 0.02 | 0.28 | 1.06 |
| 26 | 99.7 | < 0.02 | < 0.02 | < 0.02 | 20.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 125.5 | < 0.02 | < 0.02 | 2.10 | 19.84 | 0.26 | < 0.02 | 0.26 | 0.88 |
| 24 | 126 | < 0.02 | < 0.02 | < 0.02 | 19.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 149.4 | < 0.02 | < 0.02 | 1.56 | 19.31 | 0.21 | < 0.02 | 0.10 | 0.77 |
| 21 | 175.4 | < 0.02 | < 0.02 | 2.73 | 18.51 | 0.26 | < 0.02 | 0.03 | 1.01 |
| 20 | 199.9 | 217.14 | 35.626 | 3.09 | 18.24 | 0.30 | < 0.02 | 0.02 | 1.10 |
| 19 | 225.6 | < 0.02 | < 0.02 | 3.07 | 18.01 | 0.29 | < 0.02 | 0.02 | 1.10 |
| 18 | 251.1 | < 0.02 | < 0.02 | 3.37 | 17.91 | 0.30 | < 0.02 | 0.02 | 1.16 |
| 17 | 300.3 | 217.10 | 35.593 | 4.34 | 17.47 | 0.37 | < 0.02 | < 0.02 | 1.40 |
| 16 | 349.8 | < 0.02 | < 0.02 | 7.96 | 16.08 | 0.61 | < 0.02 | < 0.02 | 2.48 |
| 14 | 400.3 | < 0.02 | < 0.02 | 9.36 | 14.68 | 0.70 | < 0.02 | < 0.02 | 3.02 |
| 15 | 400.5 | < 0.02 | < 0.02 | < 0.02 | 14.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 600 | 207.09 | 34.794 | 18.45 | 10.25 | 1.26 | < 0.02 | < 0.02 | 7.10 |
| 12 | 699.3 | < 0.02 | < 0.02 | 22.08 | 8.75 | 1.50 | < 0.02 | < 0.02 | 10.74 |
| 11 | 801 | 208.48 | 34.507 | 24.40 | 7.65 | 1.67 | < 0.02 | < 0.02 | 14.33 |
| 10 | 901.3 | < 0.02 | < 0.02 | 26.63 | 6.76 | 1.81 | < 0.02 | < 0.02 | 19.56 |
| 9 | 1000.7 | < 0.02 | < 0.02 | 28.53 | 6.04 | 1.95 | < 0.02 | < 0.02 | 27.00 |
| 8 | 1101 | < 0.02 | < 0.02 | 30.40 | 5.46 | 2.07 | < 0.02 | < 0.02 | 36.39 |
| 7 | 1201.6 | < 0.02 | < 0.02 | 31.74 | 4.90 | 2.18 | < 0.02 | < 0.02 | 46.06 |
| 6 | 1403.9 | 169.49 | 34.503 | 34.09 | 3.94 | 2.36 | < 0.02 | < 0.02 | 67.73 |
| 5 | 1600.8 | < 0.02 | < 0.02 | 35.43 | 3.26 | 2.45 | < 0.02 | 0.02 | 85.11 |
| 4 | 1802.1 | < 0.02 | < 0.02 | 35.57 | 2.76 | 2.47 | < 0.02 | 0.02 | 93.50 |
| 3 | 1999.5 | 165.16 | 34.646 | 35.00 | 2.48 | 2.43 | < 0.02 | < 0.02 | 95.23 |
| 2 | 2500.8 | 184.41 | 34.713 | 33.23 | 2.02 | 2.28 | < 0.02 | < 0.02 | 97.18 |
| 1 | 3001 | 193.61 | 34.726 | 32.99 | 1.65 | 2.27 | < 0.02 | < 0.02 | 106.32 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |