Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 69
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-27 06:32 to 2023-10-27 08:48 UTC
Where: 33° 59.2' S 156° 02.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 6.4 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 6.9 | 225.58 | 35.499 | 0.02 | 22.11 | 0.12 | < 0.02 | < 0.02 | 0.08 |
| 36 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 24.7 | 225.94 | 35.499 | 0.02 | 22.12 | 0.13 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 25.9 | < 0.02 | < 0.02 | < 0.02 | 22.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 49 | < 0.02 | < 0.02 | < 0.02 | 21.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 49.2 | < 0.02 | < 0.02 | < 0.02 | 21.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 49.5 | < 0.02 | < 0.02 | 0.79 | 21.86 | 0.18 | < 0.02 | 0.08 | 0.37 |
| 25 | 75.4 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 75.5 | 193.20 | 35.596 | 3.42 | 20.98 | 0.34 | < 0.02 | 0.19 | 1.04 |
| 23 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 19.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 100.4 | 206.65 | 35.631 | 2.92 | 19.56 | 0.30 | < 0.02 | 0.21 | 0.91 |
| 21 | 125.2 | < 0.02 | < 0.02 | < 0.02 | 18.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 125.5 | < 0.02 | < 0.02 | 6.00 | 18.72 | 0.50 | < 0.02 | 0.06 | 1.70 |
| 18 | 160.3 | < 0.02 | < 0.02 | 5.77 | 17.62 | 0.48 | < 0.02 | 0.05 | 1.93 |
| 19 | 160.4 | < 0.02 | < 0.02 | < 0.02 | 17.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 200.6 | 183.60 | 35.414 | 9.22 | 16.29 | 0.68 | < 0.02 | 0.03 | 2.81 |
| 16 | 251.5 | < 0.02 | < 0.02 | 9.06 | 15.43 | 0.67 | < 0.02 | 0.02 | 2.78 |
| 15 | 301.6 | 204.73 | 35.268 | 10.27 | 14.15 | 0.76 | < 0.02 | 0.03 | 3.35 |
| 14 | 401.3 | < 0.02 | < 0.02 | 13.04 | 12.39 | 0.93 | < 0.02 | 0.02 | 4.29 |
| 13 | 500.6 | < 0.02 | < 0.02 | 17.39 | 10.50 | 1.19 | < 0.02 | 0.02 | 6.15 |
| 12 | 601.9 | 215.18 | 34.643 | 20.90 | 8.98 | 1.43 | < 0.02 | 0.02 | 8.47 |
| 11 | 699.9 | < 0.02 | < 0.02 | 24.30 | 7.84 | 1.65 | < 0.02 | < 0.02 | 13.75 |
| 10 | 801.8 | 200.89 | 34.482 | 26.46 | 7.01 | 1.80 | < 0.02 | < 0.02 | 18.86 |
| 9 | 902.1 | < 0.02 | < 0.02 | 28.09 | 6.25 | 1.92 | < 0.02 | < 0.02 | 25.23 |
| 8 | 1002.3 | < 0.02 | < 0.02 | 29.74 | 5.58 | 2.04 | < 0.02 | < 0.02 | 34.29 |
| 7 | 1200.2 | < 0.02 | < 0.02 | 32.35 | 4.51 | 2.25 | < 0.02 | < 0.02 | 54.33 |
| 6 | 1404.3 | < 0.02 | < 0.02 | 34.51 | 3.57 | 2.42 | < 0.02 | < 0.02 | 76.29 |
| 5 | 1602.9 | 159.53 | 34.585 | 35.38 | 2.97 | 2.49 | < 0.02 | < 0.02 | 90.54 |
| 4 | 1803 | < 0.02 | < 0.02 | 35.19 | 2.61 | 2.48 | < 0.02 | < 0.02 | 95.37 |
| 3 | 2002.6 | 171.68 | 34.662 | 34.30 | 2.37 | 2.41 | < 0.02 | < 0.02 | 94.08 |
| 2 | 2502.6 | 187.98 | 34.717 | 32.94 | 1.94 | 2.30 | < 0.02 | 0.02 | 98.42 |
| 1 | 3001.1 | 196.29 | 34.725 | 32.89 | 1.57 | 2.29 | < 0.02 | 0.02 | 108.06 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |