Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 68
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-27 01:47 to 2023-10-27 04:18 UTC
Where: 34° 07.4' S 156° 17.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 8.9 | < 0.02 | < 0.02 | < 0.02 | 19.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 19.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.8 | < 0.02 | < 0.02 | < 0.02 | 19.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 19.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 8.7 | < 0.02 | < 0.02 | < 0.02 | 19.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 9.3 | 230.54 | 35.536 | 0.57 | 19.94 | 0.22 | 0.28 | 0.13 | 0.72 |
| 30 | 24.7 | < 0.02 | < 0.02 | < 0.02 | 19.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 24.6 | 229.91 | 35.535 | 0.63 | 19.92 | 0.21 | 0.27 | 0.14 | 0.70 |
| 28 | 40 | < 0.02 | < 0.02 | < 0.02 | 19.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 39.9 | < 0.02 | < 0.02 | < 0.02 | 19.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 39.6 | < 0.02 | < 0.02 | 2.05 | 19.64 | 0.29 | 0.22 | 0.39 | 1.07 |
| 25 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 16.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 60.1 | < 0.02 | < 0.02 | 9.78 | 16.58 | 0.73 | < 0.02 | 0.35 | 3.26 |
| 23 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 15.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 80.5 | 175.12 | 35.356 | 10.74 | 15.94 | 0.79 | < 0.02 | 0.10 | 3.52 |
| 21 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 15.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 100.6 | 179.94 | 35.302 | 11.21 | 15.22 | 0.81 | < 0.02 | 0.07 | 3.61 |
| 19 | 150.7 | < 0.02 | < 0.02 | 13.08 | 13.69 | 0.92 | < 0.02 | 0.03 | 4.32 |
| 18 | 199.9 | 191.42 | 35.079 | 14.09 | 12.89 | 0.99 | < 0.02 | 0.02 | 4.83 |
| 17 | 249.8 | < 0.02 | < 0.02 | 15.35 | 12.02 | 1.06 | < 0.02 | < 0.02 | 5.48 |
| 16 | 299.2 | 200.17 | 34.934 | 16.34 | 11.40 | 1.14 | < 0.02 | < 0.02 | 5.91 |
| 15 | 350 | < 0.02 | < 0.02 | 18.68 | 10.39 | 1.29 | < 0.02 | < 0.02 | 7.46 |
| 14 | 400.4 | < 0.02 | < 0.02 | 20.28 | 9.57 | 1.39 | < 0.02 | < 0.02 | 8.81 |
| 13 | 500.1 | < 0.02 | < 0.02 | 22.30 | 8.53 | 1.53 | < 0.02 | < 0.02 | 10.41 |
| 12 | 599.7 | 206.96 | 34.509 | 24.58 | 7.59 | 1.68 | < 0.02 | < 0.02 | 14.79 |
| 11 | 700.8 | < 0.02 | < 0.02 | 26.43 | 6.81 | 1.81 | < 0.02 | < 0.02 | 19.38 |
| 10 | 800.5 | 198.61 | 34.445 | 28.37 | 6.15 | 1.94 | < 0.02 | < 0.02 | 26.56 |
| 9 | 900.6 | < 0.02 | < 0.02 | 29.72 | 5.62 | 2.04 | < 0.02 | < 0.02 | 33.43 |
| 8 | 1002.1 | < 0.02 | < 0.02 | 31.10 | 5.09 | 2.14 | < 0.02 | < 0.02 | 42.10 |
| 7 | 1201.4 | 171.99 | 34.491 | 33.56 | 4.05 | 2.33 | < 0.02 | < 0.02 | 63.75 |
| 6 | 1401 | < 0.02 | < 0.02 | 35.04 | 3.38 | 2.45 | < 0.02 | < 0.02 | 81.62 |
| 5 | 1600.6 | < 0.02 | < 0.02 | 35.44 | 2.91 | 2.48 | < 0.02 | < 0.02 | 91.30 |
| 4 | 1801.5 | < 0.02 | < 0.02 | 35.04 | 2.57 | 2.46 | < 0.02 | < 0.02 | 95.05 |
| 3 | 1995.4 | 169.94 | 34.666 | 34.28 | 2.35 | 2.40 | < 0.02 | < 0.02 | 95.10 |
| 2 | 2499.9 | 185.88 | 34.716 | 32.91 | 1.94 | 2.28 | < 0.02 | < 0.02 | 109.31 |
| 1 | 3003 | 194.86 | 34.724 | 32.94 | 1.53 | 2.30 | < 0.02 | < 0.02 | 109.11 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |