Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 42
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-17 20:47 to 2023-10-17 22:41 UTC
Where: 38° 24.4' S 154° 29.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.6 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 6.4 | 253.76 | 35.503 | 1.97 | 15.68 | 0.26 | 0.10 | 0.19 | 1.02 |
| 28 | 20.4 | < 0.02 | < 0.02 | < 0.02 | 15.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 21.1 | < 0.02 | < 0.02 | 1.99 | 15.65 | 0.26 | 0.11 | 0.19 | 0.96 |
| 26 | 40 | < 0.02 | < 0.02 | < 0.02 | 15.63 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 40.2 | < 0.02 | < 0.02 | 2.04 | 15.63 | 0.27 | 0.13 | 0.19 | 0.99 |
| 24 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 15.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 60.3 | < 0.02 | < 0.02 | 2.09 | 15.62 | 0.27 | 0.14 | 0.20 | 1.01 |
| 22 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 15.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 80.2 | 243.36 | 35.474 | 3.84 | 15.24 | 0.37 | 0.06 | 0.28 | 1.34 |
| 20 | 99.7 | 233.04 | 35.393 | 6.49 | 14.42 | 0.53 | < 0.02 | 0.06 | 2.03 |
| 19 | 99.6 | < 0.02 | < 0.02 | 6.50 | 14.42 | 0.53 | < 0.02 | 0.06 | 2.06 |
| 18 | 140.8 | < 0.02 | < 0.02 | 7.62 | 13.92 | 0.61 | < 0.02 | 0.04 | 2.35 |
| 17 | 141.1 | < 0.02 | < 0.02 | 7.64 | 13.92 | 0.60 | < 0.02 | 0.03 | 2.38 |
| 16 | 200.8 | 225.58 | 35.228 | 9.64 | 13.05 | 0.73 | < 0.02 | 0.02 | 2.98 |
| 15 | 251.8 | < 0.02 | < 0.02 | 10.28 | 12.32 | 0.77 | < 0.02 | 0.02 | 3.06 |
| 14 | 301.8 | 233.00 | 34.982 | 13.89 | 11.38 | 0.99 | < 0.02 | 0.02 | 4.37 |
| 13 | 399.3 | 220.00 | 34.711 | 18.74 | 9.54 | 1.29 | < 0.02 | < 0.02 | 6.42 |
| 12 | 500.4 | < 0.02 | < 0.02 | 22.22 | 8.48 | 1.51 | < 0.02 | < 0.02 | 10.10 |
| 11 | 599.6 | 203.25 | 34.507 | 25.16 | 7.47 | 1.71 | < 0.02 | < 0.02 | 15.54 |
| 10 | 701.3 | < 0.02 | < 0.02 | 26.91 | 6.79 | 1.83 | < 0.02 | < 0.02 | 20.10 |
| 9 | 799.6 | 197.27 | 34.448 | 28.38 | 6.26 | 1.93 | < 0.02 | < 0.02 | 25.44 |
| 8 | 900.1 | < 0.02 | < 0.02 | 30.04 | 5.59 | 2.06 | < 0.02 | < 0.02 | 34.10 |
| 7 | 1000.3 | 185.16 | 34.442 | 31.88 | 4.79 | 2.19 | < 0.02 | < 0.02 | 45.56 |
| 6 | 1101.4 | < 0.02 | < 0.02 | 33.18 | 4.26 | 2.29 | < 0.02 | < 0.02 | 54.81 |
| 5 | 1200.7 | 173.20 | 34.482 | 33.91 | 3.95 | 2.34 | < 0.02 | < 0.02 | 62.87 |
| 4 | 1400.3 | < 0.02 | < 0.02 | 35.24 | 3.28 | 2.45 | < 0.02 | < 0.02 | 82.20 |
| 3 | 1599.7 | 160.51 | 34.588 | 35.46 | 2.89 | 2.46 | < 0.02 | < 0.02 | 88.36 |
| 2 | 1798.8 | < 0.02 | < 0.02 | 34.95 | 2.50 | 2.43 | < 0.02 | < 0.02 | 92.71 |
| 1 | 2000.4 | 172.48 | 34.673 | 34.28 | 2.33 | 2.38 | < 0.02 | < 0.02 | 92.87 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |