Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 40
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-17 12:26 to 2023-10-17 14:17 UTC
Where: 37° 54.3' S 154° 27.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 15.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.8 | < 0.02 | < 0.02 | < 0.02 | 15.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 15.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 6.3 | 257.69 | 35.429 | 1.81 | 15.21 | 0.26 | 0.13 | 0.19 | 1.29 |
| 33 | 6.9 | < 0.02 | < 0.02 | < 0.02 | 15.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.2 | < 0.02 | < 0.02 | < 0.02 | 15.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 20 | < 0.02 | < 0.02 | 1.82 | 15.21 | 0.27 | 0.13 | 0.19 | 1.33 |
| 29 | 20.3 | < 0.02 | < 0.02 | 1.82 | 15.22 | 0.27 | 0.13 | 0.19 | 1.32 |
| 26 | 40.1 | 257.60 | 35.415 | 2.00 | 15.12 | 0.27 | 0.12 | 0.20 | 1.40 |
| 28 | 40.1 | < 0.02 | < 0.02 | 2.00 | 15.12 | 0.27 | 0.12 | 0.20 | 1.40 |
| 27 | 40.3 | < 0.02 | < 0.02 | 2.00 | 15.12 | 0.27 | 0.12 | 0.20 | 1.41 |
| 24 | 60.1 | < 0.02 | < 0.02 | 2.57 | 15.06 | 0.30 | 0.11 | 0.22 | 1.44 |
| 25 | 60.2 | < 0.02 | < 0.02 | 2.45 | 15.07 | 0.29 | 0.12 | 0.22 | 1.44 |
| 22 | 79.9 | 245.01 | 35.394 | 5.39 | 14.55 | 0.46 | < 0.02 | 0.14 | 1.80 |
| 23 | 80 | < 0.02 | < 0.02 | 5.36 | 14.54 | 0.46 | < 0.02 | 0.15 | 1.78 |
| 21 | 99.8 | < 0.02 | < 0.02 | 6.71 | 13.99 | 0.54 | < 0.02 | 0.04 | 2.07 |
| 20 | 100 | 242.78 | 35.382 | 6.71 | 13.99 | 0.54 | < 0.02 | 0.04 | 2.10 |
| 19 | 180.7 | < 0.02 | < 0.02 | 6.77 | 13.89 | 0.54 | < 0.02 | 0.02 | 2.24 |
| 18 | 220.1 | 228.22 | < 0.02 | 9.61 | 13.32 | 0.72 | < 0.02 | 0.02 | 3.14 |
| 17 | 260.1 | < 0.02 | < 0.02 | 15.69 | 11.60 | 1.10 | < 0.02 | 0.02 | 5.55 |
| 16 | 300.3 | 200.66 | 34.842 | 18.30 | 10.57 | 1.26 | < 0.02 | < 0.02 | 7.09 |
| 15 | 320.5 | < 0.02 | < 0.02 | 19.24 | 10.10 | 1.31 | < 0.02 | 0.02 | 7.79 |
| 14 | 350 | < 0.02 | < 0.02 | 20.77 | 9.45 | 1.41 | < 0.02 | 0.02 | 9.25 |
| 13 | 400.1 | < 0.02 | < 0.02 | 23.66 | 8.21 | 1.60 | < 0.02 | 0.02 | 13.21 |
| 12 | 500.4 | < 0.02 | < 0.02 | 28.24 | 6.38 | 1.92 | < 0.02 | < 0.02 | 25.53 |
| 11 | 600.5 | 190.75 | 34.436 | 30.34 | 5.45 | 2.08 | < 0.02 | < 0.02 | 35.29 |
| 10 | 700.5 | < 0.02 | < 0.02 | 31.57 | 4.93 | 2.17 | < 0.02 | < 0.02 | 43.54 |
| 9 | 800.5 | 181.90 | 34.452 | 32.18 | 4.66 | 2.22 | < 0.02 | < 0.02 | 48.44 |
| 8 | 900.1 | < 0.02 | < 0.02 | 33.33 | 4.20 | 2.31 | < 0.02 | < 0.02 | 58.45 |
| 7 | 1000.3 | 168.55 | 34.501 | 34.19 | 3.81 | 2.38 | < 0.02 | < 0.02 | 67.93 |
| 6 | 1100.6 | < 0.02 | < 0.02 | 34.74 | 3.54 | 2.42 | < 0.02 | < 0.02 | 74.34 |
| 5 | 1200.5 | 161.58 | 34.542 | 35.15 | 3.33 | 2.45 | < 0.02 | < 0.02 | 79.76 |
| 4 | 1400.6 | < 0.02 | < 0.02 | 35.46 | 2.90 | 2.48 | < 0.02 | < 0.02 | 88.66 |
| 3 | 1600 | 163.77 | 34.632 | 35.08 | 2.55 | 2.45 | < 0.02 | < 0.02 | 92.21 |
| 2 | 1799.1 | < 0.02 | < 0.02 | 34.46 | 2.37 | 2.40 | < 0.02 | < 0.02 | 92.75 |
| 1 | 2000.8 | 175.38 | 34.684 | 33.96 | 2.24 | 2.36 | < 0.02 | < 0.02 | 93.13 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |