Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 31
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-15 22:48 to 2023-10-16 00:43 UTC
Where: 35° 44.9' S 154° 19.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 4.5 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 5 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 4 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 17.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.7 | 246.62 | 35.592 | 0.07 | 17.56 | 0.12 | 0.06 | 0.03 | 0.18 |
| 29 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 17.26 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 29.7 | 248.49 | 35.569 | 0.12 | 17.26 | 0.13 | 0.05 | 0.03 | 0.20 |
| 27 | 60.8 | < 0.02 | < 0.02 | 0.14 | 17.10 | 0.14 | 0.06 | 0.04 | 0.23 |
| 26 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 17.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 79.1 | < 0.02 | < 0.02 | < 0.02 | 16.14 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 79.2 | 244.43 | 35.519 | 2.33 | 16.14 | 0.27 | 0.03 | 0.37 | 0.94 |
| 23 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 15.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 100.7 | < 0.02 | < 0.02 | < 0.02 | 15.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 100.7 | 232.95 | 35.483 | 4.63 | 15.50 | 0.40 | < 0.02 | 0.07 | 1.53 |
| 20 | 125 | < 0.02 | < 0.02 | 5.23 | 15.32 | 0.44 | < 0.02 | 0.03 | 1.62 |
| 19 | 150.2 | < 0.02 | < 0.02 | 5.33 | 15.17 | 0.45 | < 0.02 | 0.03 | 1.61 |
| 18 | 179.4 | < 0.02 | < 0.02 | 6.53 | 14.84 | 0.53 | < 0.02 | 0.02 | 1.92 |
| 17 | 200.2 | 215.04 | 35.344 | 8.12 | 14.46 | 0.62 | < 0.02 | 0.02 | 2.38 |
| 16 | 250.3 | < 0.02 | < 0.02 | 9.78 | 13.69 | 0.74 | < 0.02 | < 0.02 | 2.99 |
| 15 | 301.5 | < 0.02 | < 0.02 | 11.76 | 12.95 | 0.86 | < 0.02 | < 0.02 | 3.64 |
| 14 | 301.3 | < 0.02 | < 0.02 | 11.76 | 12.95 | 0.86 | < 0.02 | 0.02 | 3.67 |
| 13 | 403.6 | 209.50 | 34.925 | 15.68 | 11.10 | 1.10 | < 0.02 | 0.02 | 5.25 |
| 12 | 503.5 | < 0.02 | < 0.02 | 18.99 | 9.78 | 1.31 | < 0.02 | 0.02 | 7.34 |
| 11 | 602.6 | 204.90 | 34.587 | 22.96 | 8.30 | 1.57 | < 0.02 | 0.02 | 12.09 |
| 10 | 701.3 | < 0.02 | < 0.02 | 26.10 | 7.03 | 1.78 | < 0.02 | < 0.02 | 19.09 |
| 9 | 799.8 | 194.01 | 34.451 | 29.09 | 5.87 | 1.99 | < 0.02 | 0.02 | 30.87 |
| 8 | 900.2 | < 0.02 | < 0.02 | 30.82 | 5.17 | 2.11 | < 0.02 | < 0.02 | 39.23 |
| 7 | 999.5 | 182.57 | 34.455 | 31.94 | 4.74 | 2.19 | < 0.02 | < 0.02 | 47.91 |
| 6 | 1099.3 | < 0.02 | < 0.02 | 33.04 | 4.30 | 2.28 | < 0.02 | < 0.02 | 57.73 |
| 5 | 1199.9 | 170.34 | 34.500 | 33.87 | 3.94 | 2.34 | < 0.02 | < 0.02 | 66.23 |
| 4 | 1399.6 | < 0.02 | < 0.02 | 35.12 | 3.26 | 2.46 | < 0.02 | < 0.02 | 83.59 |
| 3 | 1600.4 | 158.73 | 34.602 | 35.40 | 2.80 | 2.47 | < 0.02 | < 0.02 | 91.73 |
| 2 | 1799.6 | < 0.02 | < 0.02 | 35.01 | 2.53 | 2.44 | < 0.02 | < 0.02 | 94.41 |
| 1 | 2001.4 | 169.67 | 34.665 | 34.42 | 2.35 | 2.39 | < 0.02 | < 0.02 | 93.89 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |