Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 29
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-15 06:47 to 2023-10-15 08:36 UTC
Where: 35° 25.0' S 154° 19.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 19.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 7.3 | < 0.02 | < 0.02 | < 0.02 | 19.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 19.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 19.54 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.7 | 232.86 | 35.561 | 0.85 | 19.37 | 0.20 | 0.07 | 0.13 | 0.55 |
| 31 | 19.7 | < 0.02 | < 0.02 | < 0.02 | 17.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 20.2 | < 0.02 | < 0.02 | 0.93 | 17.52 | 0.17 | 0.15 | 0.20 | 0.57 |
| 29 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 41.1 | < 0.02 | < 0.02 | < 0.02 | 17.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 41.2 | 245.14 | 35.599 | 0.97 | 17.47 | 0.17 | 0.11 | 0.21 | 0.54 |
| 26 | 60.7 | < 0.02 | < 0.02 | < 0.02 | 17.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.7 | < 0.02 | < 0.02 | 1.28 | 17.43 | 0.20 | 0.15 | 0.27 | 0.68 |
| 24 | 80.5 | < 0.02 | < 0.02 | < 0.02 | 17.16 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 80.8 | 231.52 | 35.606 | 2.90 | 17.16 | 0.31 | 0.02 | 0.50 | 1.06 |
| 21 | 100.1 | 248.63 | 35.612 | 1.87 | 17.09 | 0.27 | 0.36 | 0.41 | 0.89 |
| 22 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 17.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 125.4 | < 0.02 | < 0.02 | 5.32 | 16.51 | 0.45 | < 0.02 | 0.06 | 1.66 |
| 19 | 150.6 | < 0.02 | < 0.02 | 6.83 | 15.82 | 0.55 | < 0.02 | 0.04 | 2.07 |
| 18 | 180.5 | < 0.02 | < 0.02 | 8.01 | 15.16 | 0.62 | < 0.02 | 0.04 | 2.44 |
| 17 | 200.7 | < 0.02 | < 0.02 | 8.39 | 14.78 | 0.64 | < 0.02 | 0.03 | 2.57 |
| 16 | 220.6 | 223.89 | 35.381 | 7.11 | 14.63 | 0.57 | < 0.02 | 0.03 | 2.26 |
| 15 | 300.8 | < 0.02 | < 0.02 | 11.19 | 13.28 | 0.82 | < 0.02 | 0.03 | 3.60 |
| 14 | 350.4 | < 0.02 | < 0.02 | 11.41 | 12.45 | 0.84 | < 0.02 | 0.03 | 3.66 |
| 13 | 400.2 | 219.11 | 34.974 | 14.03 | 11.40 | 1.00 | < 0.02 | 0.03 | 4.54 |
| 12 | 500.7 | < 0.02 | < 0.02 | 19.29 | 9.49 | 1.33 | < 0.02 | 0.02 | 6.69 |
| 11 | 600.3 | 213.75 | 34.599 | 21.89 | 8.60 | 1.50 | < 0.02 | 0.02 | 9.41 |
| 10 | 701.1 | < 0.02 | < 0.02 | 24.78 | 7.70 | 1.69 | < 0.02 | 0.02 | 14.74 |
| 9 | 800.3 | 200.57 | 34.463 | 27.18 | 6.70 | 1.86 | < 0.02 | < 0.02 | 21.27 |
| 8 | 900.6 | < 0.02 | < 0.02 | 29.29 | 5.91 | 2.00 | < 0.02 | < 0.02 | 29.43 |
| 7 | 1001 | 187.58 | 34.441 | 31.08 | 5.21 | 2.13 | < 0.02 | 0.02 | 39.57 |
| 6 | 1100.6 | < 0.02 | < 0.02 | 32.33 | 4.67 | 2.23 | < 0.02 | 0.02 | 49.78 |
| 5 | 1200.8 | 172.75 | 34.485 | 33.50 | 4.17 | 2.31 | < 0.02 | 0.02 | 60.70 |
| 4 | 1400.6 | < 0.02 | < 0.02 | 35.11 | 3.39 | 2.44 | < 0.02 | 0.02 | 79.67 |
| 3 | 1600.8 | 157.30 | 34.596 | 35.63 | 2.87 | 2.48 | < 0.02 | 0.02 | 92.00 |
| 2 | 1800.4 | < 0.02 | < 0.02 | 35.21 | 2.56 | 2.45 | < 0.02 | < 0.02 | 94.56 |
| 1 | 2000.7 | 169.00 | 34.664 | 34.63 | 2.35 | 2.39 | < 0.02 | < 0.02 | 95.16 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |