Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 28
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-15 02:32 to 2023-10-15 04:33 UTC
Where: 35° 14.7' S 154° 19.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 34 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 22.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 6 | < 0.02 | < 0.02 | < 0.02 | 22.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 22.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 6.2 | 224.96 | 35.488 | 0.10 | 22.12 | 0.14 | < 0.02 | 0.03 | 0.11 |
| 36 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 22.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 20 | < 0.02 | < 0.02 | 0.74 | 22.04 | 0.19 | 0.04 | 0.08 | 0.12 |
| 30 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 21.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 30.5 | 220.71 | 35.498 | 0.33 | 21.91 | 0.16 | 0.06 | 0.06 | < 0.02 |
| 27 | 51.1 | < 0.02 | < 0.02 | 4.42 | 20.54 | 0.41 | < 0.02 | 0.15 | 1.15 |
| 28 | 51.2 | < 0.02 | < 0.02 | < 0.02 | 20.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 80.1 | 197.67 | 35.612 | 4.42 | 18.78 | 0.40 | < 0.02 | 0.05 | 1.12 |
| 26 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 100.8 | < 0.02 | < 0.02 | < 0.02 | 18.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 100.9 | < 0.02 | < 0.02 | < 0.02 | 18.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 101.3 | 234.02 | 35.629 | 1.07 | 18.14 | 0.21 | 0.32 | 0.18 | 0.34 |
| 20 | 125.8 | < 0.02 | < 0.02 | 1.00 | 17.43 | 0.19 | 0.20 | 0.11 | 0.39 |
| 21 | 125.8 | < 0.02 | < 0.02 | < 0.02 | 17.43 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 149.8 | < 0.02 | < 0.02 | < 0.02 | 16.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 149.8 | < 0.02 | < 0.02 | 0.64 | 16.95 | 0.18 | 0.21 | 0.11 | 0.17 |
| 16 | 199.5 | 238.22 | 35.490 | 4.12 | 15.48 | 0.37 | < 0.02 | 0.04 | 1.20 |
| 17 | 199.7 | < 0.02 | < 0.02 | < 0.02 | 15.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 249.8 | < 0.02 | < 0.02 | 7.64 | 14.63 | 0.59 | < 0.02 | 0.03 | 2.11 |
| 14 | 300.9 | 209.06 | 35.239 | 10.54 | 13.57 | 0.78 | < 0.02 | 0.03 | 3.08 |
| 13 | 401.6 | < 0.02 | < 0.02 | 14.81 | 11.48 | 1.04 | < 0.02 | 0.02 | 4.67 |
| 12 | 500.7 | < 0.02 | < 0.02 | 18.83 | 9.86 | 1.29 | < 0.02 | 0.02 | 6.55 |
| 11 | 600 | 208.25 | 34.602 | 22.15 | 8.57 | 1.51 | < 0.02 | 0.02 | 9.97 |
| 10 | 700.9 | < 0.02 | < 0.02 | 25.06 | 7.53 | 1.71 | < 0.02 | < 0.02 | 15.22 |
| 9 | 801.2 | 199.01 | 34.466 | 27.12 | 6.77 | 1.85 | < 0.02 | < 0.02 | 20.11 |
| 8 | 899.5 | < 0.02 | < 0.02 | 28.80 | 6.07 | 1.97 | < 0.02 | < 0.02 | 27.34 |
| 7 | 999.5 | 189.05 | 34.439 | 30.53 | 5.35 | 2.10 | < 0.02 | < 0.02 | 36.99 |
| 6 | 1101.6 | < 0.02 | < 0.02 | 32.14 | 4.66 | 2.22 | < 0.02 | < 0.02 | 47.19 |
| 5 | 1200.5 | 174.27 | 34.483 | 33.12 | 4.28 | 2.30 | < 0.02 | < 0.02 | 59.11 |
| 4 | 1400.9 | < 0.02 | < 0.02 | 34.88 | 3.50 | 2.43 | < 0.02 | < 0.02 | 78.55 |
| 3 | 1601.4 | 156.76 | 34.590 | 35.57 | 2.93 | 2.50 | < 0.02 | < 0.02 | 90.66 |
| 2 | 1801.3 | < 0.02 | < 0.02 | 35.28 | 2.56 | 2.46 | < 0.02 | 0.02 | 94.67 |
| 1 | 2001.1 | < 0.02 | 34.660 | 34.73 | 2.38 | 2.42 | < 0.02 | < 0.02 | 95.04 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |