Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 18
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-13 06:55 to 2023-10-13 08:53 UTC
Where: 33° 32.3' S 154° 19.8' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 7 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.5 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.7 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 22.38 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 6.8 | 222.32 | 35.442 | < 0.02 | 22.38 | 0.13 | < 0.02 | < 0.02 | 0.14 |
| 30 | 20.1 | 222.37 | 35.442 | < 0.02 | 22.39 | 0.13 | < 0.02 | < 0.02 | 0.14 |
| 29 | 50.4 | < 0.02 | < 0.02 | < 0.02 | 22.39 | 0.13 | < 0.02 | < 0.02 | 0.13 |
| 28 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 22.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 79.8 | < 0.02 | < 0.02 | < 0.02 | 22.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 80.3 | < 0.02 | < 0.02 | < 0.02 | 22.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 80.4 | < 0.02 | < 0.02 | < 0.02 | 22.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 22.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 79.9 | 221.56 | 35.446 | 0.07 | 22.37 | 0.13 | < 0.02 | 0.03 | 0.19 |
| 22 | 110.2 | 201.91 | 35.542 | 1.81 | 21.95 | 0.23 | < 0.02 | 0.10 | 0.61 |
| 21 | 130.2 | < 0.02 | < 0.02 | 2.05 | 21.64 | 0.25 | < 0.02 | 0.14 | 0.59 |
| 20 | 150.6 | < 0.02 | < 0.02 | 2.89 | 21.34 | 0.29 | < 0.02 | 0.20 | 0.74 |
| 19 | 170.3 | < 0.02 | < 0.02 | 5.08 | 21.05 | 0.43 | < 0.02 | 0.04 | 1.14 |
| 18 | 200.2 | 169.00 | 35.637 | 5.91 | 20.33 | 0.47 | < 0.02 | 0.03 | 1.29 |
| 17 | 240.4 | < 0.02 | < 0.02 | 3.11 | 19.60 | 0.28 | < 0.02 | 0.02 | 0.66 |
| 16 | 300.2 | 190.61 | 35.599 | 5.40 | 18.58 | 0.42 | < 0.02 | < 0.02 | 1.20 |
| 15 | 359.8 | < 0.02 | < 0.02 | 2.87 | 18.04 | 0.27 | < 0.02 | < 0.02 | 0.74 |
| 14 | 399.6 | < 0.02 | < 0.02 | 6.83 | 17.39 | 0.52 | < 0.02 | < 0.02 | 1.72 |
| 13 | 450.2 | < 0.02 | < 0.02 | 9.30 | 16.18 | 0.68 | < 0.02 | < 0.02 | 2.53 |
| 12 | 519.6 | < 0.02 | < 0.02 | 9.98 | 14.93 | 0.73 | < 0.02 | < 0.02 | 2.89 |
| 11 | 600.8 | 201.33 | 35.141 | 12.74 | 12.95 | 0.90 | < 0.02 | < 0.02 | 3.97 |
| 10 | 700.4 | < 0.02 | < 0.02 | 16.91 | 10.91 | 1.16 | < 0.02 | < 0.02 | 5.90 |
| 9 | 800.7 | 205.80 | 34.675 | 20.90 | 9.26 | 1.42 | < 0.02 | < 0.02 | 8.89 |
| 8 | 900.3 | < 0.02 | < 0.02 | 23.59 | 8.13 | 1.60 | < 0.02 | < 0.02 | 12.62 |
| 7 | 1000 | 202.72 | 34.475 | 26.30 | 6.95 | 1.78 | < 0.02 | < 0.02 | 18.89 |
| 6 | 1100 | < 0.02 | < 0.02 | 28.45 | 6.13 | 1.92 | < 0.02 | < 0.02 | 26.69 |
| 5 | 1200.6 | 189.85 | 34.442 | 30.27 | 5.43 | 2.06 | < 0.02 | < 0.02 | 36.94 |
| 4 | 1400.1 | < 0.02 | < 0.02 | 32.91 | 4.34 | 2.26 | < 0.02 | < 0.02 | 58.76 |
| 3 | 1600.2 | 161.09 | 34.538 | 34.71 | 3.53 | 2.41 | < 0.02 | < 0.02 | 78.66 |
| 2 | 1800.2 | < 0.02 | < 0.02 | 35.55 | 2.95 | 2.47 | < 0.02 | < 0.02 | 92.90 |
| 1 | 2000.2 | 161.45 | 34.634 | 35.13 | 2.57 | 2.44 | < 0.02 | < 0.02 | 94.98 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |