Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 12
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-10 10:57 to 2023-10-10 11:16 UTC
Where: 32° 53.4' S 152° 30.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 3.5 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.6 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 4.9 | 240.05 | 35.529 | < 0.02 | 20.48 | 0.10 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5.9 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 6.1 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 6.2 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 6.3 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 10.1 | 240.01 | 35.529 | < 0.02 | 20.48 | 0.11 | 0.02 | < 0.02 | < 0.02 |
| 18 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 20.48 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 18.9 | < 0.02 | < 0.02 | < 0.02 | 20.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 19.4 | < 0.02 | < 0.02 | < 0.02 | 20.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 19.5 | < 0.02 | < 0.02 | < 0.02 | 20.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 20.1 | < 0.02 | < 0.02 | < 0.02 | 20.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 20.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 20.3 | 242.96 | 35.527 | 0.38 | 20.00 | 0.14 | 0.02 | 0.04 | < 0.02 |
| 10 | 29.8 | < 0.02 | < 0.02 | < 0.02 | 18.74 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 30 | 207.23 | 35.517 | 4.53 | 18.72 | 0.43 | 0.35 | 0.17 | 1.55 |
| 7 | 49.9 | 197.80 | 35.495 | 5.74 | 18.31 | 0.50 | 0.28 | 0.18 | 1.82 |
| 8 | 50.2 | < 0.02 | < 0.02 | < 0.02 | 18.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 75 | 176.46 | 35.404 | 9.41 | 16.66 | 0.72 | 0.07 | 0.12 | 2.92 |
| 6 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 16.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 100 | 180.52 | 35.303 | 10.85 | 15.39 | 0.81 | 0.02 | 0.07 | 3.49 |
| 4 | 100.1 | < 0.02 | < 0.02 | < 0.02 | 15.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 132.9 | < 0.02 | < 0.02 | < 0.02 | 13.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 132.9 | 185.54 | 35.211 | 11.98 | 13.94 | 0.87 | 0.02 | 0.09 | 3.94 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |