Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 11
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-10 08:39 to 2023-10-10 08:59 UTC
Where: 32° 47.8' S 152° 24.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 28 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 5 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 5 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 5 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 5 | 251.89 | 35.552 | 1.19 | 18.78 | 0.25 | 0.27 | 0.14 | 1.05 |
| 35 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.3 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 9.8 | < 0.02 | < 0.02 | < 0.02 | 18.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 10.1 | 252.07 | 35.553 | 1.26 | 18.78 | 0.25 | 0.24 | 0.14 | 1.10 |
| 12 | 24.9 | < 0.02 | < 0.02 | < 0.02 | 18.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 25 | 234.92 | 35.548 | 1.68 | 18.12 | 0.27 | 0.22 | 0.20 | 0.87 |
| 13 | 25 | < 0.02 | < 0.02 | < 0.02 | 18.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 25.1 | < 0.02 | < 0.02 | < 0.02 | 18.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 18.11 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 18.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 35.2 | < 0.02 | < 0.02 | < 0.02 | 17.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 35.3 | 217.05 | 35.538 | 3.41 | 17.98 | 0.37 | 0.30 | 0.32 | 1.26 |
| 8 | 50 | < 0.02 | < 0.02 | < 0.02 | 17.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 50.1 | 194.14 | 35.498 | 6.46 | 17.28 | 0.52 | 0.05 | 0.49 | 2.05 |
| 5 | 75 | 181.90 | 35.344 | 10.47 | 15.68 | 0.77 | < 0.02 | 0.20 | 3.30 |
| 6 | 75.2 | < 0.02 | < 0.02 | < 0.02 | 15.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 99.9 | < 0.02 | < 0.02 | < 0.02 | 14.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 100.1 | < 0.02 | 35.290 | 11.33 | 14.67 | 0.85 | < 0.02 | 0.31 | 4.34 |
| 1 | 122.8 | 180.39 | 35.290 | 11.34 | 14.68 | 0.85 | < 0.02 | 0.33 | 4.37 |
| 2 | 122.9 | 180.48 | 35.291 | < 0.02 | 14.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |