Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 10
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-10 04:08 to 2023-10-10 04:53 UTC
Where: 32° 57.8' S 152° 34.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 32 | 3 | < 0.02 | < 0.02 | < 0.02 | 20.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.1 | < 0.02 | < 0.02 | < 0.02 | 20.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 20.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 20.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.2 | < 0.02 | < 0.02 | < 0.02 | 20.68 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.7 | < 0.02 | < 0.02 | < 0.02 | 20.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 4.8 | 239.07 | 35.532 | < 0.02 | 20.66 | 0.11 | < 0.02 | 0.02 | 0.03 |
| 30 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 9.9 | 239.56 | 35.528 | < 0.02 | 20.50 | 0.11 | < 0.02 | 0.02 | 0.08 |
| 24 | 9.9 | < 0.02 | < 0.02 | < 0.02 | 20.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 20 | < 0.02 | < 0.02 | < 0.02 | 20.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 20.2 | 238.67 | 35.528 | < 0.02 | 20.39 | 0.10 | < 0.02 | < 0.02 | 0.10 |
| 19 | 30 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 20.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 30.1 | < 0.02 | < 0.02 | < 0.02 | 20.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 30.1 | 236.93 | 35.529 | < 0.02 | 20.36 | 0.11 | < 0.02 | < 0.02 | 0.16 |
| 17 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 20.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 20.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 50.1 | < 0.02 | < 0.02 | < 0.02 | 18.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 50.2 | 172.17 | 35.537 | 7.42 | 18.46 | 0.59 | < 0.02 | 0.50 | 2.24 |
| 12 | 74.8 | < 0.02 | < 0.02 | < 0.02 | 16.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 75 | 169.09 | 35.420 | 9.76 | 16.85 | 0.75 | < 0.02 | 0.07 | 3.05 |
| 11 | 100.2 | 176.14 | 35.353 | 10.36 | 15.90 | 0.78 | < 0.02 | 0.03 | 3.23 |
| 10 | 100.3 | < 0.02 | < 0.02 | < 0.02 | 15.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 150.4 | 184.58 | 35.251 | 11.48 | 14.61 | 0.84 | < 0.02 | 0.02 | 3.65 |
| 8 | 150.5 | < 0.02 | < 0.02 | < 0.02 | 14.62 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 175.4 | 193.74 | 35.277 | 10.72 | 14.43 | 0.79 | < 0.02 | 0.02 | 3.20 |
| 6 | 200.2 | 192.49 | 35.213 | 11.74 | 13.95 | 0.86 | < 0.02 | 0.02 | 3.65 |
| 5 | 225.7 | 196.91 | 35.184 | 12.09 | 13.48 | 0.88 | < 0.02 | 0.02 | 3.83 |
| 4 | 250.2 | 195.88 | 35.106 | 13.35 | 12.92 | 0.95 | < 0.02 | 0.02 | 4.34 |
| 3 | 300.2 | < 0.02 | 35.046 | 14.30 | 12.29 | 1.01 | < 0.02 | 0.03 | 4.78 |
| 2 | 350.1 | < 0.02 | 34.939 | 16.04 | 11.36 | 1.12 | < 0.02 | 0.03 | 5.68 |
| 1 | 384.8 | 201.78 | 34.903 | 16.64 | 11.03 | 1.15 | < 0.02 | 0.02 | 6.05 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |