Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 9
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-10 01:29 to 2023-10-10 02:14 UTC
Where: 33° 02.0' S 152° 30.3' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 31 | 3.6 | < 0.02 | < 0.02 | < 0.02 | 20.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 3.7 | 236.88 | 35.531 | < 0.02 | 20.91 | 0.13 | < 0.02 | 0.02 | 0.31 |
| 32 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 20.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 3.7 | < 0.02 | < 0.02 | < 0.02 | 20.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 20.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 3.8 | < 0.02 | < 0.02 | < 0.02 | 20.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 20.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 20.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 3.9 | < 0.02 | < 0.02 | < 0.02 | 20.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 20.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.1 | < 0.02 | < 0.02 | < 0.02 | 20.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 10.1 | < 0.02 | < 0.02 | < 0.02 | 20.56 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 10.3 | 237.69 | 35.524 | < 0.02 | 20.56 | 0.13 | < 0.02 | 0.02 | 0.28 |
| 23 | 19.8 | < 0.02 | < 0.02 | < 0.02 | 20.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 20.2 | 237.64 | 35.523 | < 0.02 | 20.51 | 0.13 | < 0.02 | 0.02 | 0.24 |
| 18 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 29.9 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 30 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 30.2 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 30.4 | < 0.02 | < 0.02 | < 0.02 | 20.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 30.4 | 236.08 | 35.521 | 0.04 | 20.46 | 0.13 | < 0.02 | 0.02 | 0.19 |
| 15 | 40.2 | < 0.02 | < 0.02 | < 0.02 | 19.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 40.3 | 213.26 | 35.527 | 3.52 | 19.44 | 0.35 | 0.24 | 0.16 | 1.36 |
| 13 | 60.3 | < 0.02 | < 0.02 | < 0.02 | 17.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 60.4 | 170.78 | 35.502 | 8.30 | 17.99 | 0.63 | < 0.02 | 0.22 | 2.50 |
| 10 | 100.3 | 176.05 | 35.369 | 10.17 | 16.18 | 0.76 | < 0.02 | 0.02 | 3.18 |
| 11 | 100.4 | < 0.02 | < 0.02 | < 0.02 | 16.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 149.9 | 184.05 | 35.261 | 11.30 | 14.74 | 0.83 | < 0.02 | < 0.02 | 3.68 |
| 8 | 150.3 | 184.23 | 35.262 | 11.26 | 14.72 | 0.83 | < 0.02 | < 0.02 | 3.63 |
| 7 | 175.3 | 191.60 | 35.252 | 11.20 | 14.33 | 0.82 | < 0.02 | 0.02 | 3.47 |
| 6 | 200.1 | 193.69 | 35.221 | 11.62 | 13.94 | 0.84 | < 0.02 | 0.02 | 3.66 |
| 5 | 225.3 | 195.66 | 35.195 | 11.97 | 13.63 | 0.87 | < 0.02 | 0.02 | 3.78 |
| 4 | 250.3 | 196.37 | 35.131 | 12.95 | 13.14 | 0.93 | < 0.02 | < 0.02 | 4.15 |
| 3 | 300.2 | 198.96 | 35.033 | 14.53 | 12.27 | 1.02 | < 0.02 | 0.02 | 4.91 |
| 2 | 350.3 | 201.02 | 34.955 | 15.76 | 11.50 | 1.10 | < 0.02 | 0.02 | 5.51 |
| 1 | 396.5 | 201.71 | 34.914 | 16.41 | 11.15 | 1.14 | < 0.02 | 0.02 | 5.91 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |