Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 6
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-09 17:29 to 2023-10-09 18:08 UTC
Where: 33° 28.9' S 152° 03.7' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 26 | 4.7 | 228.40 | 35.576 | 0.53 | 20.20 | 0.17 | 0.08 | 0.05 | 0.62 |
| 27 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.8 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 5 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 5.1 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 5.2 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 5.5 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 10.2 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 10.4 | 227.86 | 35.576 | 0.53 | 20.20 | 0.18 | 0.08 | 0.05 | 0.59 |
| 22 | 20.1 | 228.80 | 35.576 | 0.53 | 20.20 | 0.17 | 0.09 | 0.04 | 0.62 |
| 23 | 20.2 | < 0.02 | < 0.02 | < 0.02 | 20.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 39.9 | < 0.02 | < 0.02 | < 0.02 | 20.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 39.9 | 228.84 | 35.581 | 0.74 | 20.02 | 0.19 | 0.18 | 0.06 | 0.63 |
| 18 | 60.3 | 215.71 | 35.585 | 2.10 | 19.58 | 0.27 | 0.22 | 0.29 | 0.85 |
| 19 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 19.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 17.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 80 | < 0.02 | < 0.02 | < 0.02 | 17.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 80.1 | < 0.02 | < 0.02 | < 0.02 | 17.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 80.2 | < 0.02 | < 0.02 | < 0.02 | 17.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 80.2 | 183.60 | 35.511 | 7.51 | 17.79 | 0.59 | < 0.02 | 0.08 | 2.17 |
| 11 | 100 | < 0.02 | < 0.02 | < 0.02 | 17.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 100.1 | 176.37 | 35.451 | 8.95 | 17.03 | 0.67 | < 0.02 | 0.02 | 2.59 |
| 8 | 150.1 | 187.17 | 35.363 | 9.68 | 15.57 | 0.71 | < 0.02 | < 0.02 | 2.88 |
| 9 | 150.2 | < 0.02 | < 0.02 | < 0.02 | 15.57 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 174.8 | 191.24 | 35.318 | 10.14 | 14.97 | 0.74 | < 0.02 | < 0.02 | 2.98 |
| 6 | 200.1 | 193.78 | 35.238 | 11.40 | 14.17 | 0.82 | < 0.02 | < 0.02 | 3.49 |
| 5 | 225 | 194.14 | 35.191 | 12.12 | 13.80 | 0.87 | < 0.02 | < 0.02 | 3.76 |
| 4 | 250.1 | 195.62 | 35.130 | 13.07 | 13.17 | 0.93 | < 0.02 | < 0.02 | 4.21 |
| 3 | 300.3 | 197.13 | 35.043 | 14.40 | 12.28 | 1.02 | < 0.02 | 0.02 | 4.85 |
| 2 | 350.1 | 199.23 | 34.982 | 15.38 | 11.75 | 1.08 | < 0.02 | 0.02 | 5.34 |
| 1 | 389 | 200.33 | 34.940 | 16.09 | 11.32 | 1.13 | < 0.02 | 0.03 | 5.69 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |