Please login if you have access to particular applications.
Deployment Details
Survey: - IN2023_V06 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 1
Gear: Autosal Salinometer,CDOM CTD 24 - SN 7138,CTD 24 - SN 1332,Chlorophyll - CTD 24 - Wetlabs ECO,Conductivity CTD 24 - SN 4425,Licor - CTD 24 - SN 70562,Oxygen CTD 24-SBE 43-SN 3155,Pressure CTD 24,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 24 - Wetlabs ECO,Temperature CTD 24-SN 2751,Transmissometer - CTD 24 -CST-1421DR
When: 2023-10-09 02:40 to 2023-10-09 03:19 UTC
Where: 34° 08.9' S 151° 41.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 14 | 1000 | 182.80 | 34.459 | 31.79 | 4.76 | 2.17 | < 0.02 | < 0.02 | 47.90 |
| 13 | 1000.1 | 182.66 | 34.459 | 31.75 | 4.76 | 2.18 | < 0.02 | < 0.02 | 47.91 |
| 1 | 1000.1 | 189.76 | 34.460 | 31.91 | 4.76 | 2.19 | < 0.02 | 0.02 | 48.18 |
| 30 | 1000.2 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 1000.2 | 182.13 | 34.460 | 31.93 | 4.76 | 2.18 | < 0.02 | 0.02 | 48.25 |
| 20 | 1000.2 | < 0.02 | 34.459 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 1000.2 | < 0.02 | 34.461 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 1000.2 | 182.04 | 34.460 | 31.93 | 4.76 | 2.18 | < 0.02 | 0.02 | 48.17 |
| 12 | 1000.2 | 181.86 | 34.459 | 31.74 | 4.77 | 2.18 | < 0.02 | < 0.02 | 48.05 |
| 15 | 1000.2 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 1000.2 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 1000.3 | 182.62 | 34.460 | 31.78 | 4.76 | 2.19 | < 0.02 | 0.02 | 48.22 |
| 33 | 1000.3 | < 0.02 | 34.461 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 1000.3 | < 0.02 | 34.459 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 1000.3 | 182.22 | 34.460 | 31.77 | 4.77 | 2.19 | < 0.02 | < 0.02 | 48.16 |
| 36 | 1000.3 | < 0.02 | 34.461 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 1000.3 | 181.95 | 34.460 | 31.76 | 4.77 | 2.19 | < 0.02 | 0.02 | 48.14 |
| 19 | 1000.3 | < 0.02 | 34.459 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 1000.3 | 182.17 | 34.461 | 31.84 | 4.76 | 2.19 | < 0.02 | 0.02 | 48.24 |
| 25 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 1000.3 | < 0.02 | 34.459 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 1000.3 | 182.93 | 34.461 | 31.79 | 4.77 | 2.18 | < 0.02 | 0.02 | 48.15 |
| 32 | 1000.3 | < 0.02 | 34.461 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 1000.3 | 182.35 | 34.460 | 31.88 | 4.77 | 2.19 | < 0.02 | 0.02 | 48.24 |
| 9 | 1000.3 | 182.04 | 34.460 | 31.82 | 4.77 | 2.19 | < 0.02 | < 0.02 | 48.16 |
| 10 | 1000.3 | 182.48 | 34.461 | 31.82 | 4.77 | 2.19 | < 0.02 | < 0.02 | 48.10 |
| 29 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 1000.3 | < 0.02 | 34.459 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 1000.3 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1000.4 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1000.4 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 1000.4 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1000.5 | < 0.02 | 34.460 | < 0.02 | 4.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CDOM CTD 24 - SN 7138 | WET Labs | FLCDRTD | 7138 | CDOM |
| CTD 24 - SN 1332 | Seabird | SBE9+ V_2 | 1332 | |
| Chlorophyll - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Fluorescence (arbitrary units) |
| Conductivity CTD 24 - SN 4425 | Seabird | SBE4C | 4425 | |
| Licor - CTD 24 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 24-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 24 | Digiquartz | 410K-134 | 1332 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 24 - Wetlabs ECO | WET Labs | FLBBNTU | 6890 | Turbidity (%) |
| Temperature CTD 24-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 24 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |