Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 100
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-03-02 07:27 to 2024-03-02 07:45 UTC
Where: 34° 27.5' S 115° 05.4' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 7 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 7.1 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.4 | 235.63 | 35.680 | 0.02 | 19.17 | 0.14 | < 0.02 | 0.03 | 0.58 |
| 36 | 7.5 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 14.5 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 15.1 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 15.6 | 235.63 | 35.680 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 15.7 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 15.9 | < 0.02 | < 0.02 | < 0.02 | 19.19 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 16.2 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 24.8 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 25 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 25.1 | 235.27 | 35.680 | 0.02 | 19.16 | 0.14 | < 0.02 | 0.03 | 0.56 |
| 21 | 25.2 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 25.4 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 19.18 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 37.6 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 38 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 38.1 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 38.4 | 234.65 | 35.678 | 0.04 | 19.08 | 0.15 | 0.03 | 0.03 | 0.59 |
| 14 | 38.7 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 38.7 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 46 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 46.1 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 46.2 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 46.2 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 46.2 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 46.2 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 46.2 | 234.11 | 35.679 | 0.06 | 19.08 | 0.14 | 0.04 | 0.03 | 0.55 |
| 8 | 46.2 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 46.3 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 46.3 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 46.4 | < 0.02 | < 0.02 | < 0.02 | 19.08 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 46.6 | < 0.02 | < 0.02 | < 0.02 | 19.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |