Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 97
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-03-01 23:41 to 2024-03-02 00:22 UTC
Where: 34° 57.0' S 115° 00.6' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 8.1 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 9.7 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 9.8 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 10.1 | 229.07 | 35.848 | < 0.02 | 20.97 | 0.05 | < 0.02 | 0.02 | 1.40 |
| 33 | 10.6 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 25.6 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 25.9 | 229.16 | 35.849 | < 0.02 | 20.97 | 0.03 | < 0.02 | 0.02 | 1.37 |
| 30 | 26.3 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 26.3 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 26.5 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 40.4 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 40.6 | 229.16 | 35.849 | < 0.02 | 20.97 | 0.04 | < 0.02 | 0.02 | 1.41 |
| 23 | 40.9 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 41.2 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 41.3 | < 0.02 | < 0.02 | < 0.02 | 20.97 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 65.1 | < 0.02 | < 0.02 | < 0.02 | 20.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 65.3 | < 0.02 | < 0.02 | < 0.02 | 20.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 65.5 | < 0.02 | < 0.02 | < 0.02 | 20.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 65.5 | 231.17 | 35.842 | < 0.02 | 20.48 | 0.04 | < 0.02 | 0.02 | 1.34 |
| 17 | 75.1 | < 0.02 | < 0.02 | < 0.02 | 20.07 | 0.05 | 0.02 | 0.02 | 1.30 |
| 14 | 95.1 | < 0.02 | < 0.02 | < 0.02 | 18.76 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 95.2 | 235.36 | 35.734 | 0.15 | 18.75 | 0.11 | 0.08 | 0.14 | 1.34 |
| 16 | 95.2 | < 0.02 | < 0.02 | < 0.02 | 18.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 95.4 | < 0.02 | < 0.02 | < 0.02 | 18.78 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 110.3 | < 0.02 | < 0.02 | < 0.02 | 18.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 110.4 | 235.14 | 35.715 | 0.46 | 18.02 | 0.14 | < 0.02 | 0.29 | 1.45 |
| 10 | 110.4 | < 0.02 | < 0.02 | < 0.02 | 18.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 110.4 | < 0.02 | < 0.02 | < 0.02 | 18.01 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 160 | < 0.02 | < 0.02 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 160.2 | < 0.02 | < 0.02 | < 0.02 | 16.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 160.2 | 235.81 | 35.645 | 1.20 | 16.66 | 0.20 | < 0.02 | 0.13 | 1.54 |
| 5 | 180.1 | < 0.02 | < 0.02 | 2.13 | 15.48 | 0.28 | < 0.02 | 0.07 | 1.46 |
| 2 | 200.4 | < 0.02 | < 0.02 | < 0.02 | 14.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 200.5 | < 0.02 | < 0.02 | < 0.02 | 14.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 200.7 | 240.68 | 35.466 | 2.54 | 14.79 | 0.32 | < 0.02 | 0.04 | 1.35 |
| 3 | 200.7 | < 0.02 | < 0.02 | < 0.02 | 14.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |