Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 96
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-03-01 21:22 to 2024-03-01 22:31 UTC
Where: 35° 03.1' S 115° 00.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 10 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 10.8 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 11 | 230.32 | 35.856 | < 0.02 | 20.80 | 0.05 | < 0.02 | 0.02 | 1.40 |
| 34 | 11.9 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 19.7 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 19.9 | 230.14 | 35.856 | < 0.02 | 20.80 | 0.04 | < 0.02 | 0.02 | 1.50 |
| 32 | 20 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 21 | < 0.02 | < 0.02 | < 0.02 | 20.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 60.2 | 231.30 | 35.828 | < 0.02 | 20.50 | 0.05 | < 0.02 | 0.02 | 1.39 |
| 27 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 20.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 20.51 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 60.4 | < 0.02 | < 0.02 | < 0.02 | 20.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 19.40 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 70.4 | < 0.02 | < 0.02 | < 0.02 | 19.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 70.5 | 234.47 | 35.763 | < 0.02 | 19.42 | 0.09 | 0.03 | 0.05 | 1.19 |
| 23 | 70.7 | < 0.02 | < 0.02 | < 0.02 | 19.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 120.3 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 120.6 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 120.8 | 233.00 | 35.701 | 0.85 | 17.46 | 0.17 | < 0.02 | 0.09 | 1.70 |
| 19 | 121.1 | < 0.02 | < 0.02 | < 0.02 | 17.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 191.2 | 238.13 | 35.565 | 1.79 | 15.60 | 0.25 | < 0.02 | 0.04 | 1.46 |
| 14 | 191.3 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 191.3 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 191.4 | < 0.02 | < 0.02 | < 0.02 | 15.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 290.5 | 244.92 | 35.197 | 5.24 | 12.98 | 0.49 | < 0.02 | 0.04 | 1.06 |
| 11 | 290.7 | < 0.02 | < 0.02 | < 0.02 | 12.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 290.7 | < 0.02 | < 0.02 | < 0.02 | 12.95 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 420.5 | < 0.02 | < 0.02 | 13.84 | 10.53 | 0.98 | < 0.02 | 0.03 | 3.48 |
| 8 | 520.1 | < 0.02 | < 0.02 | < 0.02 | 9.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 520.2 | 237.73 | 34.691 | 17.79 | 9.28 | 1.23 | < 0.02 | 0.03 | 5.46 |
| 6 | 571.1 | < 0.02 | < 0.02 | 19.59 | 8.82 | 1.34 | < 0.02 | 0.02 | 7.33 |
| 4 | 620.8 | 207.09 | 34.465 | 26.13 | 6.97 | 1.76 | < 0.02 | 0.02 | 16.88 |
| 5 | 620.8 | < 0.02 | < 0.02 | < 0.02 | 6.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 680.8 | < 0.02 | < 0.02 | 28.61 | 6.04 | 1.93 | < 0.02 | 0.02 | 23.57 |
| 2 | 760.4 | < 0.02 | < 0.02 | < 0.02 | 5.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 760.5 | 197.13 | 34.391 | 30.55 | 5.14 | 2.08 | < 0.02 | 0.02 | 31.34 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |