Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 94
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-03-01 05:55 to 2024-03-01 08:04 UTC
Where: 35° 30.5' S 115° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.9 | 233.22 | 35.839 | 0.02 | 20.22 | 0.04 | < 0.02 | 0.02 | 1.03 |
| 36 | 6 | < 0.02 | < 0.02 | < 0.02 | 20.22 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 24.4 | 232.82 | 35.838 | 0.02 | 20.21 | 0.03 | < 0.02 | 0.02 | 1.03 |
| 32 | 50.6 | 233.53 | < 0.02 | < 0.02 | 20.11 | 0.03 | < 0.02 | < 0.02 | 0.97 |
| 33 | 50.7 | < 0.02 | < 0.02 | < 0.02 | 20.12 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 70.1 | 251.31 | 35.573 | < 0.02 | 17.51 | 0.09 | < 0.02 | < 0.02 | 0.85 |
| 29 | 90.2 | 254.39 | 35.441 | 0.12 | 15.50 | 0.17 | < 0.02 | 0.06 | 0.68 |
| 30 | 90.4 | < 0.02 | < 0.02 | < 0.02 | 15.49 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 120.2 | < 0.02 | < 0.02 | < 0.02 | 14.39 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 120.3 | 244.56 | 35.351 | 2.29 | 14.37 | 0.31 | < 0.02 | 0.05 | 0.74 |
| 26 | 160 | 244.47 | 35.268 | 3.81 | 13.59 | 0.40 | < 0.02 | 0.03 | 0.82 |
| 25 | 260 | < 0.02 | < 0.02 | < 0.02 | 12.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 260.1 | 242.02 | 35.084 | 8.34 | 12.04 | 0.67 | < 0.02 | 0.02 | 1.59 |
| 22 | 380.3 | 244.52 | 34.851 | 13.31 | 10.45 | 0.96 | < 0.02 | < 0.02 | 2.93 |
| 23 | 380.4 | < 0.02 | < 0.02 | < 0.02 | 10.46 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 480.2 | 241.04 | 34.768 | 15.81 | 9.84 | 1.11 | < 0.02 | 0.02 | 3.89 |
| 19 | 650.6 | 230.99 | 34.586 | 20.36 | 8.50 | 1.39 | < 0.02 | 0.02 | 7.45 |
| 20 | 650.8 | < 0.02 | < 0.02 | < 0.02 | 8.50 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 775.9 | 202.76 | 34.438 | 27.15 | 6.63 | 1.83 | < 0.02 | < 0.02 | 18.76 |
| 17 | 990.8 | < 0.02 | < 0.02 | < 0.02 | 4.29 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 990.9 | 194.50 | 34.380 | 32.37 | 4.29 | 2.21 | < 0.02 | 0.02 | 40.92 |
| 16 | 991.4 | < 0.02 | < 0.02 | < 0.02 | 4.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1150.2 | 176.23 | 34.449 | 34.43 | 3.54 | 2.38 | < 0.02 | 0.02 | 58.52 |
| 12 | 1351.4 | 164.49 | 34.534 | 35.20 | 3.10 | 2.45 | < 0.02 | < 0.02 | 72.23 |
| 13 | 1351.6 | < 0.02 | < 0.02 | < 0.02 | 3.10 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 1540.8 | 160.78 | 34.606 | 34.99 | 2.86 | 2.45 | < 0.02 | < 0.02 | 81.93 |
| 11 | 1541 | < 0.02 | < 0.02 | < 0.02 | 2.86 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 1790.1 | 164.04 | 34.669 | 34.27 | 2.61 | 2.40 | < 0.02 | < 0.02 | 90.54 |
| 9 | 1790.3 | < 0.02 | < 0.02 | < 0.02 | 2.61 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 2004.8 | < 0.02 | < 0.02 | < 0.02 | 2.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 2004.9 | 169.31 | 34.702 | 33.69 | 2.41 | 2.36 | < 0.02 | < 0.02 | 96.43 |
| 7 | 2005 | < 0.02 | < 0.02 | < 0.02 | 2.41 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 2225.8 | 177.04 | 34.723 | 33.12 | 2.17 | 2.32 | < 0.02 | < 0.02 | 100.99 |
| 4 | 2226.2 | < 0.02 | < 0.02 | < 0.02 | 2.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 2336.5 | 179.63 | 34.727 | 32.88 | 2.07 | 2.31 | < 0.02 | < 0.02 | 102.93 |
| 2 | 2336.6 | < 0.02 | < 0.02 | < 0.02 | 2.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |