Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 93
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-03-01 00:10 to 2024-03-01 04:29 UTC
Where: 35° 38.9' S 115° 00.2' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.9 | 236.52 | 35.766 | 0.02 | 19.69 | 0.04 | < 0.02 | < 0.02 | 0.65 |
| 36 | 4.9 | < 0.02 | < 0.02 | < 0.02 | 19.69 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 25.8 | 236.61 | 35.762 | 0.02 | 19.67 | 0.04 | < 0.02 | < 0.02 | 0.65 |
| 34 | 25.8 | < 0.02 | < 0.02 | < 0.02 | 19.67 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 54.8 | 237.06 | 35.756 | 0.02 | 19.63 | 0.04 | < 0.02 | < 0.02 | 0.69 |
| 32 | 55.1 | < 0.02 | < 0.02 | < 0.02 | 19.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 85.1 | 253.85 | 35.439 | 0.33 | 15.64 | 0.16 | 0.02 | 0.09 | 0.82 |
| 30 | 85.1 | < 0.02 | < 0.02 | < 0.02 | 15.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 155.5 | 246.84 | 35.213 | 4.52 | 13.15 | 0.44 | < 0.02 | 0.03 | 0.92 |
| 27 | 230.5 | 243.05 | 35.093 | 8.18 | 12.09 | 0.66 | < 0.02 | 0.02 | 1.53 |
| 25 | 310.3 | 258.36 | 34.838 | 11.34 | 10.60 | 0.85 | < 0.02 | < 0.02 | 2.39 |
| 26 | 310.3 | < 0.02 | < 0.02 | < 0.02 | 10.60 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 24 | 425.5 | 243.89 | 34.765 | 15.03 | 9.96 | 1.06 | < 0.02 | < 0.02 | 3.52 |
| 23 | 575.4 | 241.35 | 34.645 | 18.23 | 9.03 | 1.26 | < 0.02 | 0.02 | 5.35 |
| 22 | 650.8 | 229.24 | 34.568 | 20.78 | 8.39 | 1.42 | < 0.02 | < 0.02 | 7.86 |
| 21 | 775.6 | 203.56 | 34.447 | 26.76 | 6.81 | 1.79 | < 0.02 | 0.02 | 17.47 |
| 19 | 945.4 | 196.46 | 34.379 | 31.48 | 4.70 | 2.15 | < 0.02 | < 0.02 | 36.04 |
| 20 | 945.9 | < 0.02 | < 0.02 | < 0.02 | 4.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1101.1 | 183.87 | 34.422 | 33.88 | 3.69 | 2.34 | < 0.02 | < 0.02 | 53.13 |
| 17 | 1285.1 | 167.84 | 34.510 | 35.08 | 3.18 | 2.44 | < 0.02 | < 0.02 | 68.78 |
| 16 | 1565.1 | < 0.02 | < 0.02 | < 0.02 | 2.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1565.2 | 161.40 | 34.615 | 34.88 | 2.82 | 2.45 | < 0.02 | < 0.02 | 83.12 |
| 14 | 1935.5 | 170.02 | 34.699 | 33.68 | 2.43 | 2.36 | < 0.02 | < 0.02 | 95.01 |
| 13 | 2355.9 | 176.77 | 34.726 | 33.31 | 2.09 | 2.33 | < 0.02 | < 0.02 | 105.24 |
| 12 | 2755.1 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2755.2 | 187.35 | 34.733 | 32.72 | 1.81 | 2.29 | < 0.02 | < 0.02 | 108.56 |
| 9 | 3124.6 | 194.01 | 34.731 | 32.49 | 1.58 | 2.27 | < 0.02 | < 0.02 | 112.79 |
| 10 | 3124.7 | < 0.02 | < 0.02 | < 0.02 | 1.58 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 3525.6 | 198.07 | 34.726 | 32.62 | 1.42 | 2.28 | < 0.02 | < 0.02 | 117.09 |
| 8 | 3525.8 | < 0.02 | < 0.02 | < 0.02 | 1.42 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 6 | 3925.3 | 202.49 | 34.721 | 32.63 | 1.26 | 2.28 | < 0.02 | < 0.02 | 120.50 |
| 5 | 4435.6 | 207.18 | 34.714 | 32.59 | 1.15 | 2.27 | < 0.02 | < 0.02 | 122.67 |
| 3 | 4925.8 | 211.43 | 34.708 | 32.63 | 1.05 | 2.28 | < 0.02 | 0.02 | 124.47 |
| 4 | 4926.2 | < 0.02 | < 0.02 | < 0.02 | 1.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 5153.6 | 212.01 | 34.707 | 32.66 | 1.04 | 2.27 | < 0.02 | < 0.02 | 124.95 |
| 2 | 5153.9 | < 0.02 | < 0.02 | < 0.02 | 1.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |