Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 91
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-28 17:54 to 2024-02-28 22:24 UTC
Where: 36° 31.8' S 114° 59.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 8.6 | 235.72 | 35.777 | < 0.02 | 19.71 | 0.04 | < 0.02 | 0.02 | 0.45 |
| 36 | 8.6 | < 0.02 | < 0.02 | < 0.02 | 19.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 20.3 | 236.03 | 35.777 | < 0.02 | 19.72 | 0.04 | < 0.02 | 0.02 | 0.45 |
| 34 | 20.7 | < 0.02 | < 0.02 | < 0.02 | 19.72 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 55.7 | < 0.02 | < 0.02 | < 0.02 | 18.96 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 55.8 | 241.88 | 35.662 | < 0.02 | 18.91 | 0.06 | < 0.02 | < 0.02 | 0.55 |
| 30 | 70.1 | < 0.02 | < 0.02 | < 0.02 | 17.21 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 70.2 | 251.13 | 35.484 | < 0.02 | 17.25 | 0.11 | 0.02 | < 0.02 | 0.73 |
| 27 | 90.7 | 245.37 | 35.467 | 1.05 | 15.27 | 0.22 | < 0.02 | 0.07 | 0.74 |
| 28 | 90.8 | < 0.02 | < 0.02 | < 0.02 | 15.27 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 120.5 | 241.88 | 35.409 | 2.24 | 14.38 | 0.31 | < 0.02 | 0.03 | 0.78 |
| 25 | 190.7 | 245.32 | 35.222 | 4.70 | 13.09 | 0.46 | < 0.02 | 0.03 | 0.91 |
| 24 | 290.3 | 243.89 | 35.014 | 9.92 | 11.52 | 0.76 | < 0.02 | 0.02 | 1.97 |
| 23 | 400.2 | 241.75 | 34.844 | 13.89 | 10.36 | 0.99 | < 0.02 | 0.02 | 3.14 |
| 22 | 600.6 | 238.53 | 34.669 | 18.13 | 9.15 | 1.23 | < 0.02 | 0.02 | 5.42 |
| 21 | 751.7 | 229.65 | 34.477 | 25.28 | 7.29 | 1.69 | < 0.02 | 0.02 | 14.30 |
| 19 | 982.7 | 194.28 | 34.379 | 32.08 | 4.45 | 2.18 | < 0.02 | < 0.02 | 39.05 |
| 20 | 982.9 | < 0.02 | < 0.02 | < 0.02 | 4.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1250.9 | 174.85 | 34.470 | 34.72 | 3.29 | 2.40 | < 0.02 | < 0.02 | 62.58 |
| 16 | 1550.6 | 162.16 | 34.612 | 34.98 | 2.81 | 2.45 | < 0.02 | < 0.02 | 82.41 |
| 17 | 1550.7 | < 0.02 | < 0.02 | < 0.02 | 2.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1902.1 | 168.55 | 34.685 | 33.93 | 2.47 | 2.37 | < 0.02 | < 0.02 | 91.60 |
| 14 | 2300.9 | 174.71 | 34.723 | 33.51 | 2.14 | 2.35 | < 0.02 | < 0.02 | 104.81 |
| 13 | 2501.7 | 178.82 | 34.729 | 33.26 | 2.01 | 2.33 | < 0.02 | < 0.02 | 106.82 |
| 11 | 2851.6 | 188.78 | 34.734 | 32.61 | 1.80 | 2.28 | < 0.02 | < 0.02 | 108.04 |
| 12 | 2851.8 | < 0.02 | < 0.02 | < 0.02 | 1.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 10 | 3300.3 | 194.99 | 34.730 | 32.65 | 1.52 | 2.28 | < 0.02 | < 0.02 | 107.97 |
| 9 | 3799.7 | 200.89 | 34.722 | 32.69 | 1.31 | 2.28 | < 0.02 | < 0.02 | 119.63 |
| 8 | 4200.9 | 204.28 | 34.718 | 32.71 | 1.21 | 2.29 | < 0.02 | < 0.02 | 122.43 |
| 7 | 4600.6 | 209.68 | 34.711 | 32.68 | 1.07 | 2.28 | < 0.02 | 0.02 | 124.25 |
| 6 | 5000 | < 0.02 | < 0.02 | < 0.02 | 0.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 5000.1 | 213.08 | 34.705 | 32.79 | 0.98 | 2.29 | < 0.02 | 0.02 | 125.80 |
| 3 | 5300.5 | 212.68 | 34.705 | 32.83 | 1.00 | 2.29 | < 0.02 | < 0.02 | 126.24 |
| 4 | 5300.6 | < 0.02 | < 0.02 | < 0.02 | 1.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 5486.7 | 212.77 | 34.705 | 32.80 | 1.02 | 2.28 | < 0.02 | 0.02 | 126.22 |
| 2 | 5486.8 | < 0.02 | < 0.02 | < 0.02 | 1.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |