Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 90
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-28 09:10 to 2024-02-28 13:19 UTC
Where: 37° 02.4' S 115° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 36 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 19.36 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 4.5 | 236.03 | 35.753 | < 0.02 | 19.36 | 0.05 | < 0.02 | 0.02 | 0.57 |
| 34 | 30.2 | 238.36 | 35.754 | < 0.02 | 19.37 | 0.04 | < 0.02 | 0.02 | 0.60 |
| 33 | 65.4 | < 0.02 | < 0.02 | < 0.02 | 19.17 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 65.8 | 240.14 | 35.725 | < 0.02 | 19.17 | 0.06 | < 0.02 | 0.02 | 0.64 |
| 31 | 90 | < 0.02 | < 0.02 | < 0.02 | 15.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 90.1 | 252.83 | 35.476 | 0.12 | 15.96 | 0.17 | < 0.02 | 0.08 | 0.65 |
| 29 | 150 | 244.47 | 35.331 | 2.86 | 14.06 | 0.36 | < 0.02 | 0.04 | 0.77 |
| 28 | 250.1 | 241.44 | 35.223 | 5.71 | 12.93 | 0.53 | < 0.02 | 0.03 | 1.04 |
| 27 | 400.6 | 244.30 | 34.842 | 13.01 | 10.53 | 0.95 | < 0.02 | 0.02 | 2.68 |
| 26 | 550 | 240.72 | 34.759 | 16.01 | 9.79 | 1.12 | < 0.02 | 0.03 | 3.87 |
| 25 | 700.4 | 238.85 | 34.638 | 18.64 | 8.94 | 1.28 | < 0.02 | 0.02 | 5.64 |
| 23 | 850.6 | 208.66 | 34.480 | 25.10 | 7.37 | 1.69 | < 0.02 | 0.02 | 13.98 |
| 24 | 850.7 | < 0.02 | < 0.02 | < 0.02 | 7.37 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 1075.2 | 196.06 | 34.377 | 31.56 | 4.70 | 2.15 | < 0.02 | 0.02 | 36.13 |
| 22 | 1075.4 | < 0.02 | < 0.02 | < 0.02 | 4.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 1375.1 | 173.28 | 34.482 | 34.81 | 3.23 | 2.41 | < 0.02 | 0.02 | 64.33 |
| 19 | 1705.9 | < 0.02 | < 0.02 | < 0.02 | 2.80 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1705.9 | 161.94 | 34.621 | 34.86 | 2.80 | 2.44 | < 0.02 | 0.02 | 84.06 |
| 17 | 2050.7 | 168.10 | 34.694 | 33.89 | 2.47 | 2.37 | < 0.02 | 0.02 | 95.03 |
| 16 | 2259.2 | 174.13 | 34.716 | 33.34 | 2.28 | 2.32 | < 0.02 | 0.02 | 99.23 |
| 15 | 2600.6 | 181.59 | 34.729 | 32.94 | 2.02 | 2.30 | < 0.02 | 0.02 | 104.64 |
| 13 | 2950.1 | 190.26 | 34.732 | 32.49 | 1.77 | 2.26 | < 0.02 | < 0.02 | 108.29 |
| 14 | 2950.3 | < 0.02 | < 0.02 | < 0.02 | 1.77 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 3200.1 | 195.53 | 34.731 | 32.41 | 1.60 | 2.26 | < 0.02 | 0.02 | 111.18 |
| 11 | 3500.4 | 200.39 | 34.727 | 32.38 | 1.41 | 2.25 | < 0.02 | 0.02 | 114.94 |
| 10 | 3800.3 | 203.12 | 34.721 | 32.50 | 1.28 | 2.27 | < 0.02 | 0.02 | 118.84 |
| 9 | 4100.4 | 206.20 | 34.716 | 32.60 | 1.17 | 2.27 | < 0.02 | 0.02 | 121.47 |
| 8 | 4400.8 | 209.59 | 34.711 | 32.59 | 1.07 | 2.28 | < 0.02 | 0.02 | 123.50 |
| 7 | 4700.5 | 212.72 | 34.706 | 32.66 | 0.98 | 2.28 | < 0.02 | < 0.02 | 125.07 |
| 6 | 5000.2 | 213.66 | 34.704 | 32.67 | 0.97 | 2.29 | < 0.02 | 0.02 | 125.90 |
| 5 | 5380.7 | 213.88 | 34.703 | 32.74 | 1.00 | 2.29 | < 0.02 | 0.02 | 126.31 |
| 4 | 5680.2 | 214.02 | 34.702 | 32.74 | 1.03 | 2.29 | < 0.02 | 0.02 | 126.26 |
| 3 | 5780.6 | 236.17 | 34.702 | 32.78 | 1.04 | 2.29 | < 0.02 | 0.02 | 126.58 |
| 1 | 5820.2 | 257.56 | 34.703 | 32.74 | 1.04 | 2.28 | < 0.02 | 0.02 | 126.29 |
| 2 | 5820.4 | < 0.02 | < 0.02 | < 0.02 | 1.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |