Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 88
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-27 16:28 to 2024-02-27 20:26 UTC
Where: 37° 59.9' S 115° 00.0' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.7 | 253.05 | 35.136 | 0.44 | 16.93 | 0.22 | 0.14 | 0.04 | 0.30 |
| 36 | 5.7 | < 0.02 | < 0.02 | < 0.02 | 16.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 33 | 30.5 | 253.09 | 35.135 | 0.44 | 16.94 | 0.21 | 0.14 | 0.04 | 0.20 |
| 34 | 30.8 | < 0.02 | < 0.02 | < 0.02 | 16.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 60.2 | < 0.02 | < 0.02 | < 0.02 | 16.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 60.4 | 249.57 | 35.227 | 0.87 | 16.40 | 0.24 | 0.43 | 0.07 | 0.44 |
| 30 | 75.6 | 251.08 | 35.328 | 1.69 | 14.32 | 0.29 | < 0.02 | 0.17 | 0.70 |
| 29 | 120.9 | < 0.02 | < 0.02 | < 0.02 | 13.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 120.9 | 249.34 | 35.199 | 5.02 | 13.09 | 0.47 | < 0.02 | 0.03 | 1.05 |
| 27 | 161.1 | 254.61 | 35.074 | 6.28 | 12.23 | 0.55 | < 0.02 | 0.02 | 1.26 |
| 26 | 225.5 | 257.29 | 34.943 | 9.21 | 11.37 | 0.72 | < 0.02 | 0.02 | 1.82 |
| 25 | 305.9 | 257.96 | 34.850 | 11.13 | 10.72 | 0.83 | < 0.02 | 0.02 | 2.22 |
| 23 | 431.2 | 252.42 | 34.751 | 14.06 | 10.02 | 1.00 | < 0.02 | 0.02 | 3.20 |
| 24 | 431.2 | < 0.02 | < 0.02 | < 0.02 | 10.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 585.5 | 243.13 | 34.698 | 16.73 | 9.51 | 1.16 | < 0.02 | 0.02 | 4.34 |
| 21 | 735.3 | 233.53 | 34.588 | 19.99 | 8.59 | 1.37 | < 0.02 | 0.02 | 7.01 |
| 20 | 875.4 | 207.14 | 34.460 | 25.75 | 7.14 | 1.73 | < 0.02 | 0.02 | 15.13 |
| 18 | 1050.4 | 205.17 | 34.354 | 30.48 | 5.05 | 2.06 | < 0.02 | 0.02 | 28.94 |
| 19 | 1050.5 | < 0.02 | < 0.02 | < 0.02 | 5.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1350.3 | 177.66 | 34.453 | 34.50 | 3.42 | 2.38 | < 0.02 | 0.02 | 59.55 |
| 15 | 1650.2 | 165.42 | 34.570 | 35.08 | 2.89 | 2.43 | < 0.02 | 0.02 | 76.12 |
| 16 | 1650.4 | < 0.02 | < 0.02 | < 0.02 | 2.89 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1900.2 | 164.53 | 34.656 | 34.40 | 2.65 | 2.40 | < 0.02 | < 0.02 | 88.07 |
| 13 | 2200.9 | 173.15 | 34.706 | 33.36 | 2.39 | 2.34 | < 0.02 | < 0.02 | 94.18 |
| 12 | 2525.5 | 185.03 | 34.732 | 32.37 | 2.10 | 2.26 | < 0.02 | 0.02 | 97.35 |
| 10 | 2850.8 | 194.77 | 34.739 | 31.88 | 1.84 | 2.22 | < 0.02 | 0.02 | 100.93 |
| 11 | 2850.9 | < 0.02 | < 0.02 | < 0.02 | 1.84 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 3150.6 | 200.30 | 34.736 | 31.92 | 1.60 | 2.22 | < 0.02 | 0.02 | 106.94 |
| 8 | 3451.3 | 204.10 | 34.727 | 32.28 | 1.35 | 2.24 | < 0.02 | 0.02 | 114.21 |
| 7 | 3750 | 207.18 | 34.717 | 32.58 | 1.15 | 2.26 | < 0.02 | 0.02 | 120.11 |
| 6 | 4051 | 212.63 | 34.707 | 32.64 | 0.95 | 2.26 | < 0.02 | 0.02 | 123.63 |
| 5 | 4350.3 | 213.79 | 34.704 | 32.74 | 0.89 | 2.28 | < 0.02 | < 0.02 | 125.90 |
| 3 | 4650.6 | 214.24 | 34.703 | 32.79 | 0.90 | 2.27 | < 0.02 | < 0.02 | 126.61 |
| 4 | 4650.7 | < 0.02 | < 0.02 | < 0.02 | 0.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 4874.2 | < 0.02 | < 0.02 | < 0.02 | 0.92 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4874.2 | 214.37 | 34.702 | 32.80 | 0.92 | 2.28 | < 0.02 | < 0.02 | 126.85 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |