Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 78
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-23 09:16 to 2024-02-23 12:38 UTC
Where: 43° 30.0' S 115° 00.1' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 5.4 | 266.49 | 34.752 | 4.47 | 14.20 | 0.46 | 0.09 | 0.11 | 0.16 |
| 36 | 5.4 | < 0.02 | < 0.02 | < 0.02 | 14.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 25.2 | 266.36 | 34.753 | 4.46 | 14.20 | 0.45 | 0.09 | 0.11 | 0.16 |
| 32 | 45.2 | 265.91 | 34.765 | 4.55 | 13.97 | 0.46 | 0.19 | 0.11 | 0.24 |
| 33 | 45.5 | < 0.02 | < 0.02 | < 0.02 | 13.98 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 56.9 | < 0.02 | < 0.02 | < 0.02 | 13.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 56.9 | 265.82 | 34.713 | 5.76 | 13.22 | 0.57 | 0.71 | 0.14 | 0.19 |
| 29 | 84.6 | 264.66 | 34.816 | 10.80 | 10.93 | 0.82 | < 0.02 | 0.13 | 2.50 |
| 28 | 110.3 | 266.22 | 34.782 | 11.41 | 10.59 | 0.86 | < 0.02 | 0.04 | 2.58 |
| 27 | 205.2 | 267.52 | 34.745 | 12.42 | 10.15 | 0.92 | < 0.02 | 0.03 | 2.94 |
| 26 | 350.4 | 263.50 | 34.730 | 13.26 | 9.94 | 0.96 | < 0.02 | 0.02 | 3.15 |
| 24 | 505.3 | 246.75 | 34.700 | 15.84 | 9.66 | 1.11 | < 0.02 | 0.02 | 4.11 |
| 25 | 505.3 | < 0.02 | < 0.02 | < 0.02 | 9.66 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 705.2 | 238.13 | 34.621 | 18.74 | 8.92 | 1.29 | < 0.02 | 0.02 | 5.99 |
| 23 | 705.4 | < 0.02 | < 0.02 | < 0.02 | 8.93 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 905.3 | 210.58 | 34.428 | 26.26 | 6.80 | 1.77 | < 0.02 | 0.02 | 16.34 |
| 21 | 905.4 | < 0.02 | < 0.02 | < 0.02 | 6.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 1124.9 | 210.67 | 34.328 | 31.09 | 4.55 | 2.11 | < 0.02 | < 0.02 | 31.70 |
| 19 | 1125 | < 0.02 | < 0.02 | < 0.02 | 4.55 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1425.3 | < 0.02 | < 0.02 | < 0.02 | 3.23 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1425.3 | 187.89 | 34.424 | 34.32 | 3.23 | 2.36 | < 0.02 | < 0.02 | 55.32 |
| 15 | 1749.8 | < 0.02 | < 0.02 | < 0.02 | 2.73 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 1749.8 | 174.58 | 34.583 | 34.38 | 2.72 | 2.37 | < 0.02 | < 0.02 | 72.40 |
| 13 | 2025.1 | 180.16 | 34.679 | 33.00 | 2.50 | 2.26 | < 0.02 | < 0.02 | 79.26 |
| 12 | 2375 | 191.28 | 34.733 | 31.65 | 2.24 | 2.17 | < 0.02 | < 0.02 | 84.73 |
| 10 | 2725.1 | 223.13 | 34.747 | 31.13 | 1.90 | 2.13 | < 0.02 | < 0.02 | 91.53 |
| 11 | 2725.2 | < 0.02 | < 0.02 | < 0.02 | 1.90 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 2975.4 | 205.22 | 34.740 | 31.43 | 1.62 | 2.16 | < 0.02 | < 0.02 | 100.36 |
| 8 | 3225.3 | 208.57 | 34.728 | 31.86 | 1.34 | 2.19 | < 0.02 | < 0.02 | 109.15 |
| 7 | 3525.5 | 212.41 | 34.714 | 32.42 | 1.06 | 2.22 | < 0.02 | < 0.02 | 118.12 |
| 6 | 3825 | 214.28 | 34.707 | 32.52 | 0.96 | 2.24 | < 0.02 | < 0.02 | 121.70 |
| 5 | 4125.1 | 215.89 | 34.704 | 32.69 | 0.91 | 2.25 | < 0.02 | < 0.02 | 123.80 |
| 4 | 4299.9 | 215.85 | 34.702 | 32.69 | 0.90 | 2.25 | < 0.02 | < 0.02 | 124.66 |
| 3 | 4475 | 215.67 | 34.702 | 32.73 | 0.90 | 2.26 | < 0.02 | 0.02 | 125.09 |
| 1 | 4518.7 | 215.58 | 34.703 | 32.78 | 0.91 | 2.27 | < 0.02 | 0.02 | 125.12 |
| 2 | 4518.8 | < 0.02 | < 0.02 | < 0.02 | 0.91 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |