Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 57
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-15 04:25 to 2024-02-15 05:00 UTC
Where: 54° 22.2' S 114° 59.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 33 | 7.4 | < 0.02 | < 0.02 | < 0.02 | 5.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 35 | 7.6 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 36 | 7.7 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 7.7 | 317.18 | 33.855 | 24.84 | 4.99 | 1.66 | 0.41 | 0.27 | 4.47 |
| 32 | 7.8 | < 0.02 | < 0.02 | < 0.02 | 5.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 8 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 34.4 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 30 | 34.7 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 34.8 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 35.1 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 25 | 35.1 | 317.27 | 33.855 | 24.82 | 4.99 | 1.66 | 0.41 | 0.27 | 4.51 |
| 28 | 35.2 | < 0.02 | < 0.02 | < 0.02 | 4.99 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 23 | 79.9 | < 0.02 | < 0.02 | < 0.02 | 4.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 80.3 | 320.35 | 33.865 | 25.14 | 4.70 | 1.68 | 0.47 | 0.27 | 5.11 |
| 24 | 80.7 | < 0.02 | < 0.02 | < 0.02 | 4.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 89.9 | 325.04 | 33.888 | 25.71 | 4.06 | 1.78 | 0.72 | 0.27 | 7.67 |
| 21 | 90 | < 0.02 | < 0.02 | < 0.02 | 4.06 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 90.1 | < 0.02 | < 0.02 | < 0.02 | 4.09 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 90.1 | < 0.02 | < 0.02 | < 0.02 | 4.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 18 | 90.2 | < 0.02 | < 0.02 | < 0.02 | 4.07 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 90.5 | < 0.02 | < 0.02 | < 0.02 | 4.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 13 | 129.8 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 129.8 | < 0.02 | < 0.02 | < 0.02 | 1.82 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 129.9 | 330.67 | 33.932 | 28.96 | 1.80 | 2.07 | 0.39 | 0.41 | 23.59 |
| 12 | 130 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 14 | 130 | < 0.02 | < 0.02 | < 0.02 | 1.81 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 9 | 159.9 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 160.2 | 318.43 | 33.995 | 30.40 | 1.31 | 2.10 | < 0.02 | 0.03 | 29.54 |
| 10 | 160.3 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 8 | 160.4 | < 0.02 | < 0.02 | < 0.02 | 1.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 400.2 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 2 | 400.3 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 5 | 400.4 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 400.4 | 183.78 | 34.481 | 35.48 | 2.33 | 2.45 | < 0.02 | 0.02 | 69.30 |
| 6 | 400.4 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 400.8 | < 0.02 | < 0.02 | < 0.02 | 2.33 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |