Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 52
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-09 12:44 to 2024-02-09 17:18 UTC
Where: 56° 48.3' S 114° 59.5' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 9.7 | 332.77 | 33.853 | 26.50 | 3.47 | 1.70 | 0.19 | 0.27 | 8.53 |
| 36 | 9.9 | < 0.02 | < 0.02 | < 0.02 | 3.47 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 31.3 | 332.68 | 33.853 | 26.42 | 3.47 | 1.71 | 0.19 | 0.27 | 8.55 |
| 33 | 55.7 | < 0.02 | < 0.02 | < 0.02 | 3.34 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 32 | 56 | 334.56 | 33.859 | 26.48 | 3.31 | 1.72 | 0.20 | 0.26 | 8.59 |
| 30 | 70.3 | 340.36 | 33.875 | 26.74 | 2.65 | 1.78 | 0.32 | 0.25 | 9.84 |
| 31 | 70.6 | < 0.02 | < 0.02 | < 0.02 | 2.64 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 29 | 110.2 | < 0.02 | < 0.02 | < 0.02 | 2.05 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 28 | 110.3 | 336.21 | 33.905 | 27.63 | 2.06 | 1.98 | 0.87 | 0.26 | 18.85 |
| 27 | 180.6 | < 0.02 | < 0.02 | < 0.02 | 0.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 26 | 180.6 | 305.57 | 34.074 | 31.41 | 0.94 | 2.17 | 0.19 | 0.14 | 38.70 |
| 24 | 260.3 | 203.43 | 34.358 | 35.65 | 2.15 | 2.44 | < 0.02 | 0.02 | 60.76 |
| 25 | 260.4 | < 0.02 | < 0.02 | < 0.02 | 2.15 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 21 | 510.5 | 174.67 | 34.589 | 35.10 | 2.32 | 2.39 | < 0.02 | 0.02 | 76.90 |
| 23 | 510.6 | < 0.02 | < 0.02 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 510.7 | < 0.02 | < 0.02 | < 0.02 | 2.32 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 20 | 810 | 183.47 | 34.695 | 33.08 | 2.15 | 2.26 | < 0.02 | < 0.02 | 82.53 |
| 18 | 1109.9 | 193.87 | 34.735 | 31.78 | 1.94 | 2.17 | < 0.02 | < 0.02 | 87.19 |
| 19 | 1109.9 | < 0.02 | < 0.02 | < 0.02 | 1.94 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 17 | 1380.7 | < 0.02 | < 0.02 | < 0.02 | 1.70 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1380.8 | 200.71 | 34.742 | 31.41 | 1.70 | 2.16 | < 0.02 | < 0.02 | 92.89 |
| 14 | 1600.1 | 204.06 | 34.739 | 31.48 | 1.52 | 2.17 | < 0.02 | < 0.02 | 97.89 |
| 15 | 1600.2 | < 0.02 | < 0.02 | < 0.02 | 1.52 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 12 | 1950.2 | 207.85 | 34.728 | 31.91 | 1.24 | 2.21 | < 0.02 | < 0.02 | 106.95 |
| 13 | 1950.2 | < 0.02 | < 0.02 | < 0.02 | 1.24 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 11 | 2350.3 | 211.51 | 34.711 | 32.52 | 0.91 | 2.25 | < 0.02 | < 0.02 | 117.16 |
| 10 | 2700.2 | 238.40 | 34.699 | 32.92 | 0.68 | 2.29 | < 0.02 | < 0.02 | 123.58 |
| 8 | 3125.1 | 222.05 | 34.686 | 33.14 | 0.44 | 2.30 | < 0.02 | < 0.02 | 130.69 |
| 9 | 3125.2 | < 0.02 | < 0.02 | < 0.02 | 0.44 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 3550 | 226.39 | 34.677 | 33.25 | 0.30 | 2.31 | < 0.02 | < 0.02 | 134.77 |
| 5 | 3975.2 | 230.27 | 34.671 | 33.25 | 0.20 | 2.30 | < 0.02 | < 0.02 | 137.07 |
| 6 | 3975.3 | < 0.02 | < 0.02 | < 0.02 | 0.20 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 4 | 4400.1 | 236.44 | 34.663 | 33.15 | 0.06 | 2.29 | < 0.02 | < 0.02 | 136.57 |
| 2 | 4590.4 | < 0.02 | < 0.02 | < 0.02 | 0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 3 | 4590.8 | < 0.02 | < 0.02 | < 0.02 | 0.03 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4591.1 | 238.67 | 34.660 | 33.09 | 0.03 | 2.29 | < 0.02 | < 0.02 | 137.11 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |