Please login if you have access to particular applications.
Deployment Details
Survey: - IN2024_V01 [details]
Deployment Type: - CTD Cast / Hydrology
Cast: 50
Gear: Autosal Salinometer,CTD 25 - SN 1354,Chlorophyll - CTD 25 - Wetlabs ECO,Conductivity CTD 25 - SN 4774,Licor - CTD 25 - SN 70562,Oxygen CTD 25-SBE 43-SN 3155,Pressure CTD 25,SCRIPPS Automated Photometric Oxygen System,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,SEAL AutoAnalyzer 3 HR,Scattering - CTD 25 - Wetlabs ECO,Temperature CTD 25-SN 2751,Transmissometer - CTD 25 -CST-1421DR
When: 2024-02-08 07:43 to 2024-02-08 11:21 UTC
Where: 57° 59.8' S 114° 59.9' E
Maximum Depth (m): unknown
View two CTD profiles of Salinity versus Fluorescence and Temperature versus Oxygen.
Bottle Data
| Bottle Number |
Pressure |
Oxygen (µM) |
Salinity (psu) |
Nitrate (µM) |
Temperature (deg C) |
Orthophosphate (µM) |
Ammonia (µM) |
Nitrite (µM) |
Silicate (µM) |
|---|---|---|---|---|---|---|---|---|---|
| 35 | 4.3 | 334.78 | 33.855 | 26.53 | 3.14 | 1.71 | 0.20 | 0.27 | 8.69 |
| 36 | 4.3 | < 0.02 | < 0.02 | < 0.02 | 3.13 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 34 | 24.8 | 335.14 | 33.854 | 26.48 | 3.05 | 1.72 | 0.20 | 0.26 | 8.63 |
| 33 | 45 | 338.17 | 33.877 | 26.67 | 2.76 | 1.76 | 0.25 | 0.25 | 10.93 |
| 32 | 57.3 | < 0.02 | < 0.02 | < 0.02 | 2.65 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 31 | 57.3 | 339.02 | 33.879 | 26.61 | 2.65 | 1.76 | 0.27 | 0.24 | 11.22 |
| 30 | 95.1 | 339.60 | 33.906 | 26.99 | 2.18 | 1.84 | 0.59 | 0.25 | 14.60 |
| 29 | 130.4 | 338.08 | 33.943 | 28.15 | 1.12 | 2.04 | 0.96 | 0.23 | 25.19 |
| 28 | 200.6 | < 0.02 | < 0.02 | < 0.02 | 1.04 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 27 | 200.7 | 283.60 | 34.145 | 32.53 | 1.04 | 2.25 | < 0.02 | 0.03 | 45.20 |
| 26 | 255.2 | 206.24 | 34.347 | 35.30 | 2.10 | 2.43 | < 0.02 | 0.02 | 59.55 |
| 25 | 405.3 | 179.05 | 34.518 | 35.48 | 2.26 | 2.45 | < 0.02 | < 0.02 | 72.86 |
| 23 | 550.4 | 175.07 | 34.615 | 34.50 | 2.28 | 2.38 | < 0.02 | < 0.02 | 78.16 |
| 24 | 550.5 | < 0.02 | < 0.02 | < 0.02 | 2.28 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 22 | 830 | 183.82 | 34.698 | 32.80 | 2.15 | 2.27 | < 0.02 | < 0.02 | 82.55 |
| 21 | 1170.1 | 195.57 | 34.738 | 31.50 | 1.92 | 2.18 | < 0.02 | < 0.02 | 87.20 |
| 20 | 1330.1 | < 0.02 | < 0.02 | < 0.02 | 1.79 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 19 | 1330.1 | 199.41 | 34.743 | 31.31 | 1.79 | 2.15 | < 0.02 | < 0.02 | 90.77 |
| 17 | 1550.2 | 203.34 | 34.740 | 31.43 | 1.59 | 2.17 | < 0.02 | < 0.02 | 95.97 |
| 18 | 1550.3 | < 0.02 | < 0.02 | < 0.02 | 1.59 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 16 | 1720 | < 0.02 | < 0.02 | < 0.02 | 1.45 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 15 | 1720 | 205.40 | 34.737 | 31.60 | 1.45 | 2.16 | < 0.02 | < 0.02 | 100.79 |
| 14 | 1915 | 207.50 | 34.731 | 31.83 | 1.29 | 2.19 | < 0.02 | < 0.02 | 105.44 |
| 13 | 2216.8 | 210.53 | 34.718 | 32.31 | 1.04 | 2.23 | < 0.02 | < 0.02 | 112.92 |
| 12 | 2494.8 | 213.21 | 34.707 | 32.69 | 0.84 | 2.26 | < 0.02 | < 0.02 | 119.25 |
| 11 | 2820.5 | 217.14 | 34.695 | 32.99 | 0.62 | 2.29 | < 0.02 | < 0.02 | 124.79 |
| 10 | 3110.1 | 221.47 | 34.686 | 33.15 | 0.45 | 2.30 | < 0.02 | < 0.02 | 129.11 |
| 9 | 3410 | 225.23 | 34.680 | 33.23 | 0.34 | 2.31 | < 0.02 | < 0.02 | 132.43 |
| 8 | 3720.3 | < 0.02 | < 0.02 | < 0.02 | 0.25 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 7 | 3720.3 | 228.44 | 34.675 | 33.28 | 0.25 | 2.31 | < 0.02 | < 0.02 | 134.97 |
| 6 | 4020 | 232.10 | 34.670 | 33.23 | 0.17 | 2.31 | < 0.02 | < 0.02 | 136.10 |
| 5 | 4410 | 236.08 | 34.664 | 33.19 | 0.08 | 2.30 | < 0.02 | < 0.02 | 135.61 |
| 3 | 4600 | 239.70 | 34.658 | 33.12 | 0.02 | 2.30 | < 0.02 | < 0.02 | 134.75 |
| 4 | 4600 | < 0.02 | < 0.02 | < 0.02 | 0.02 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
| 1 | 4641.8 | 239.92 | 34.657 | 33.09 | 0.00 | 2.28 | < 0.02 | < 0.02 | 135.03 |
| 2 | 4641.9 | < 0.02 | < 0.02 | < 0.02 | 0.00 | < 0.02 | < 0.02 | < 0.02 | < 0.02 |
Gear / Instruments used.
| Instrument | Manufacturer | Model | Serial No | Measuring |
|---|---|---|---|---|
| Autosal Salinometer | Guildline Instruments | 8400B | SN 72088 | Salinity (psu) |
| CTD 25 - SN 1354 | Seabird | SBE911 | 1354 | |
| Chlorophyll - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Fluorescence (arbitrary units) |
| Conductivity CTD 25 - SN 4774 | Seabird | SBE4C | 4774 | |
| Licor - CTD 25 - SN 70562 | QCP | 2300HP | 70562 | PAR (uE/m**2/sec) |
| Oxygen CTD 25-SBE 43-SN 3155 | Seabird | SBE 43 | 3155 | Oxygen (µM) |
| Pressure CTD 25 | Digiquartz | 410K-134 | 1354 | Pressure (decibars) |
| SCRIPPS Automated Photometric Oxygen System | SCRIPPS | Oxygen (µM) | ||
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrite (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Nitrate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Orthophosphate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Silicate (µM) | |
| SEAL AutoAnalyzer 3 HR | Seal Analytical | AA3 HR | Ammonia (µM) | |
| Scattering - CTD 25 - Wetlabs ECO | WET Labs | FLBBNTU | 6765 | Turbidity (%) |
| Temperature CTD 25-SN 2751 | Seabird | SBE-3plus | 2751 | Temperature (deg C) |
| Transmissometer - CTD 25 -CST-1421DR | WET Labs | C-Star | CST-1421DR | Transmittance (%) |